Background: The "Suspected Blood Indicator" (SBI), a feature included in the software for interpretation of capsule endoscopy (CE), is designed to facilitate detection of bleeding lesions in the small bowel. This study evaluated the sensitivity and the specificity of the SBI in patients who underwent CE for obscure GI bleeding (OGIB).

Methods: CE recordings from patients with OGIB recruited in 7 centers were read by experts blinded to the red SBI tags. They classified lesions of interest as bleeding or as having a potential for bleeding that was high (P2), low (P1), or absent (P0). The SBI tags then were marked by a another investigator. Concordance was acknowledged when frames selected by the expert reader, and those tagged by the SBI had the same time code.

Results: A total of 156 recordings were evaluated. In 83, there was either no lesion (n = 71) or a P0 lesion (n = 12); these CE recordings were regarded as normal. Among the 73 abnormal recordings, 114 P2 and 92 P1 lesions were identified. A total of 154 red tags were analyzed. Sensitivity, specificity, and positive and negative predictive values of SBI were 37%, 59%, 50%, and 46%, respectively, for detection of the presence of a P2 or P1 lesion in front of a red tag.

Conclusions: SBI-based detection of intestinal lesions with the potential for bleeding is of limited clinical value in practice and does not reduce the time required for interpretation of CE.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0016-5107(04)02587-8DOI Listing

Publication Analysis

Top Keywords

"suspected blood
8
blood indicator"
8
detection bleeding
8
bleeding lesions
8
sensitivity specificity
8
sbi tags
8
potential bleeding
8
bleeding
6
sbi
6
lesions
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!