A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of commercially available fluid-warming devices for use in forward surgical and combat areas. | LitMetric

The fluid-warming capabilities of four individual fluid warmers, i.e., Level 1, FMS 2000, Thermal Angel, and Ranger, were compared to evaluate their potential for medical use in forward military echelons of care. Lactated Ringer's solution (LR) and Hextend at room temperature (20 degrees C) or refrigerated temperature (4-7 degrees C) and packed red blood cells at 4 degrees C to 7 degrees C were used with each warmer at two different flow rates. The FMS 2000 consistently warmed all fluids to approximately 37 degrees C, regardless of the starting temperature or flow rate. The Level 1 and Ranger also efficiently warmed all fluids except cold LR to approximately 37 degrees C. The Thermal Angel generally warmed room temperature fluid, cold Hextend, and packed red blood cells to at least 33 degrees C to 34 degrees C but could not warm cold LR. The clinical standard is to have fluids warmed to 32 degrees C at a minimum and more preferably to 34 degrees C to 35 degrees C. Of the fluid warmers tested, only the Thermal Angel failed to achieve such a temperature in warming cold LR. Data from the present study suggest the Ranger and FMS 2000 to be operationally adaptable to at least echelons 1 and 2, respectively, whereas far-forward use of the Thermal Angel has limitations.

Download full-text PDF

Source
http://dx.doi.org/10.7205/milmed.170.1.76DOI Listing

Publication Analysis

Top Keywords

thermal angel
16
fms 2000
12
degrees degrees
12
degrees
11
fluid warmers
8
room temperature
8
packed red
8
red blood
8
blood cells
8
cells degrees
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!