A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Primary stability of shoulder arthrodesis using cannulated cancellous screws. | LitMetric

There are no biomechanical studies available concerned with the primary stability of shoulder arthrodesis. The aim of our biomechanical investigations was to ascertain a minimal material combination with high primary stability for shoulder arthrodesis. For that purpose, the primary stability of 6 different forms of screw arthrodesis was investigated under the stress of abduction, adduction, anteversion, and retroversion. The mean values of the screw arthrodeses were compared with those of a 16-hole plate arthrodesis. All tests were carried out on 24 human specimens without destruction by use of a materials testing machine. The most stable form of screw arthrodesis for the load directions of abduction, adduction, anteversion, and retroversion results from a specific configuration of screws comprising 3 horizontal humeroglenoid screws and 3 vertical acromiohumeral screws (318.5 +/- 99.0 N). For three forms of arthrodesis, each with 3 humerus-glenoid screws (299.9 +/- 95.4 N), no significant difference (P = .530) was found compared with a 16-hole plate arthrodesis (293.4 +/- 89.3 N). The plate arthrodeses only achieved higher power values on abduction and adduction stress in comparison with screw arthrodesis with 3 humerus-glenoid screws. The difference was insignificant. Because arthrodesis with 3 humerus-glenoid screws was significantly more stable on stress of anteversion and retroversion, this particular screw arthrodesis is considered superior to plate arthrodeses. The use of the most stable form of screw arthrodesis may reduce nonunion.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jse.2004.05.007DOI Listing

Publication Analysis

Top Keywords

screw arthrodesis
20
primary stability
16
stability shoulder
12
arthrodesis
12
shoulder arthrodesis
12
abduction adduction
12
anteversion retroversion
12
arthrodesis humerus-glenoid
12
humerus-glenoid screws
12
adduction anteversion
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!