The purpose of this study was to evaluate the importance of different image-capturing conditions, which might influence the characteristics of radiographs and, consequently, impact calculations of bone mineral density (BMD) and Metacarpal Index (MCI) using digital X-ray radiogrammetry (DXR). Radiographs of the left hand of deceased males were acquired three times using systematically varied parameters: 4-8 miliamp seconds (mA); 40-52 kV; film-focus distance (FFD); 90-130 cm; film sensitivity, 200/400; and different image modalities (conventional vs original digital radiographs as well as digital printouts). Furthermore, the interradiograph reproducibility using both conventional equipment and printouts vs originals of digital images and the intraradiograph reproducibility (either conventional or digital printouts) were evaluated. All BMD and MCI measurements were obtained with the DXR technology. The interradiograph reproducibility of DXR-BMD using conventional images under standardized conditions (6 mAs; 42 kV; 1 m FFD; film sensitivity of 200) was calculated to be coefficient of variation (CV) = 0.49% for Agfa Curix film and CV = 0.33% for Kodak T-MAT-Plus film, whereas reproducibility error using digital images ranged from CV = 0.57% (digital printouts; Philips) to CV = 1.50% (original digital images; Siemens). The intraradiograph reproducibility error was observed to be CV = 0.13% (conventional; Kodak film) vs CV = 0.27% (digital printouts; Philips). The BMD calculation was not noticeably affected by changes of FFD, exposure level, or film sensitivity/film brand, but was influenced by tube voltage (CV = 0.99% for Kodak film to CV = 2.05% for Siemens digital printouts). No significant differences were observed between the BMD and MCI data. DXR provides measurements of MCI and BMD with high precision and reproducibility. The measurements are unaffected by all tested image-capturing conditions, with the exception of tube voltage. In addition, different digital image devices clearly have an effect on DXR reproducibility.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1385/jcd:8:1:087 | DOI Listing |
Physiol Meas
May 2024
Department of Biomedical Informatics, Emory University, Atlanta, GA 30322, United States of America.
Cardiovascular diseases are a major cause of mortality globally, and electrocardiograms (ECGs) are crucial for diagnosing them. Traditionally, ECGs are stored in printed formats. However, these printouts, even when scanned, are incompatible with advanced ECG diagnosis software that require time-series data.
View Article and Find Full Text PDFVaccine
October 2024
Faculty of Medicine, Dentistry and Health Sciences, University of Melbourne, Parkville, VIC, Australia; Murdoch Children's Research Institute, Parkville, VIC, Australia.
Background: Catch-up vaccination is a personalised process through which children with missing recommended vaccinations or incomplete vaccination records are brought up to date with the Australian vaccination schedule. Navigating childhood catch-up vaccination can be difficult for migrant parents with inadequate health system knowledge and competing priorities during settlement. This study aimed to understand the experiences of migrant parents with childhood catch-up vaccination and co-design an intervention to improve the process.
View Article and Find Full Text PDFMed Sci Monit
May 2024
Faculty of Materials & Chemical Engineering, University of Miskolc, Miskolc, Hungary.
BACKGROUND Computer-aided design (CAD) has been used in the Nuss procedure to determine the bar length and shape. Despite computer aid, the shape and design remain quite intuitive. We tested a new algorithm to determine the optimal bar shape.