Magnification error in fan-beam densitometers varies with distance from the X-ray source to the bone measured and might obscure bone mineral changes in the growing skeleton. Magnification was examined by scanning aluminum rods of different shapes (square, rectangular, solid round, and hollow round) at four distances above the X-ray source in two orientations, with rods aligned parallel (SI) and perpendicular (ML) to the longitudinal axis of the scanning table. Measured area (cm(2)) decreased linearly with distance above the X-ray source for all rods in the SI orientation (p < 0.005). Measured mineral content (g) decreased linearly with distance but only for SI round rods (p < 0.0001) and for ML hollow round rods (p < 0.005). Area and mineral content decreased 1.6-1.8% per centimeter above the source for round rods. Measured mineral density (g/cm(2)) decreased linearly with distance from the source only for ML hollow round rods (p < 0.005). Variation in area, mineral content, and mineral density measurements was 6.6-6.9%, 6.9-7.5%, and 1.9-2.3%, respectively, for SI round rods. Magnification errors of this magnitude are problematic for clinical studies using fan-beam densitometry. Particularly in pediatric subjects, increases in soft tissue during normal growth could increase a bone's distance from the fan-beam source and result in apparent reductions in area and bone mineral content.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1385/jcd:8:1:057 | DOI Listing |
Int J Surg
January 2025
Department of Orthopedics, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Purpose: Congenital pseudarthrosis of the tibia (CPT) is a rare condition typically manifesting within the first decade of life. The primary objectives of surgical intervention for CPT include achieving long-term bony union of the tibia, preventing or minimizing limb length discrepancies (LLD), avoiding mechanical axis deviations of the tibia and adjacent joints, and preventing refracture. This study aims to conduct a systematic review of current treatment methods for CPT to determine the most effective non-surgical and surgical management strategies for pediatric patients with this condition.
View Article and Find Full Text PDFEur J Mass Spectrom (Chichester)
June 2024
Laboratory of Quadrupole Mass Spectrometry, Ryazan State University named after S.A. Yesenin, Ryazan, Russia.
We consider the operation of a digital linear ion trap with resonance radial ejection and mass selective instability modes. Periodic wave shape has a positive part with amplitude and duration and negative part with amplitude and duration , where is the period. The mapping of the stability diagram, calculations of the well's depth and ion oscillations spectra are presented.
View Article and Find Full Text PDFSpine (Phila Pa 1976)
December 2024
Department of Research, Gillette Children's, Saint Paul, MN.
Study Design: Modified Delphi consensus study.
Objective: To develop consensus-based best practices for the care of pediatric patients who have implanted programmable devices (IPDs) and require spinal deformity surgery.
Summary Of Background Data: Implanted programmable devices (IPDs) are often present in patients with neuromuscular or syndromic scoliosis who require spine surgery.
Phys Rev E
December 2023
Department of Mathematics, University of Pavia, Via Ferrata 5, 27100 Pavia, Italy.
Chromonic nematics are lyotropic liquid crystals that have already been known for half a century, but have only recently raised interest for their potential applications in life sciences. Determining elastic constants and anchoring strengths for rigid substrates has thus become a priority in the characterization of these materials. Here we present a method to determine chromonics' planar anchoring strength.
View Article and Find Full Text PDFJ Am Soc Mass Spectrom
January 2024
School of Mechanical Engineering, Sichuan University, Chengdu, Sichuan 610064, P. R. China.
The calculation and analysis of electric fields are indispensable steps in the design of mass spectrometry. In this work, an approach for this calculation was established based on the method of fundamental solution (MFS). It was proved to be much faster and more accurate than the other popular methods, and its optimum parameters were found for the calculation of different quadrupole fields.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!