Topographic and biomechanical differences between hyperopic and myopic laser in situ keratomileusis.

J Cataract Refract Surg

Pepose Vision Institute and the Department of Ophthalmology and Visual Sciences, Washington University School of Medicine, St. Louis, Missouri, USA.

Published: January 2005

Purpose: To evaluate the size, shape, and uniformity of the videokeratographic functional optical zone (FOZ) after laser in situ keratomileusis (LASIK) in 2 cohorts of patients with equivalent amounts of preoperative myopic or hyperopic astigmatism.

Setting: Pepose Vision Institute, St. Louis, Missouri, USA.

Methods: Eyes with myopic or hyperopic astigmatism (n=27 in each group) that had LASIK with the Visx Star S3 laser were retrospectively selected to match for level of preoperative refractive error. Slit-scanning videokeratography was performed preoperatively and 6 months postoperatively and analyzed using custom software. The FOZ was calculated by analyzing refractive power maps using a region-growing algorithm. Difference maps were generated from slit images and compared for interval change in corneal elevation, tangential curvature, and refractive power. The difference maps were also averaged (mean difference maps) for each target population. A Zernike decomposition of corneal first-surface elevation was performed to compare postoperative values with baseline parameters.

Results: The mean postoperative refractive sphere at 6 months was -0.17 diopter (D) +/- 0.66 (SD) and +0.25 +/- 0.85 D in the myopia group and hyperopia group, respectively, and the mean postoperative astigmatism, -0.49 +/- 0.32 D and -0.65 +/- 0.52 D, respectively (P=.11). Based on the refractive power maps, the mean preoperative and postoperative myopic FOZ was 33.09 +/- 7.30 mm(2) and 30.94 +/- 5.43 mm(2), respectively, and the mean hyperopic FOZ, 33.19 +/- 7.96 mm(2) and 37.99 +/- 6.88 mm(2), respectively. After LASIK, there was an increase in magnitude of negative anterior corneal surface spherical-like Zernike values in the myopia group (P<.0001) and an increase in magnitude of positive spherical-like Zernike values in the hyperopia group. Postoperatively, significant induction of corneal surface horizontal coma was noted in hyperopic eyes (P<.0001). Hyperopic eyes, on average, had larger topographic FOZs after LASIK, but with less uniformity of curvature and power change than myopic eyes.

Conclusions: Hyperopic LASIK, which involves more transition points along the ablation diameter, produced a less uniform topographic FOZ than typical myopic treatments. Less predictable biomechanical changes from the circumferential release of tension on collagen bundles after midperipheral hyperopic ablation and greater variation in beam centration and the angle of incidence may contribute to the greater variability in corneal curvature and power in hyperopic LASIK than in myopic LASIK.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcrs.2004.10.043DOI Listing

Publication Analysis

Top Keywords

refractive power
12
difference maps
12
laser situ
8
situ keratomileusis
8
myopic hyperopic
8
power maps
8
+/-
8
myopia group
8
refractive
5
maps
5

Similar Publications

Astigmatism in Duane Retraction Syndrome.

BMC Ophthalmol

January 2025

Medical Laboratories Techniques Department, College of Health and Medical Techniques, Al-Mustaqbal University, Babylon, 51001, Iraq.

Purpose: To compare the prevalence, magnitude, and type of astigmatism among patients with different Duane Retraction Syndrome (DRS) types.

Method: This retrospective cross-sectional study reviewed the records of 312 DRS patients. Patients were categorized into DRS Types 1, 2, 3, and bilateral cases.

View Article and Find Full Text PDF

Semitransparent perovskite solar cells (ST-PSCs) for building-integrated photovoltaics (BIPV) face the challenge of achieving high efficiency due to significant light loss. The SnO2 electron transport layer (ETL), utilized in n-i-p PSCs and prepared via the sol-gel method, is susceptible to aggregation on substrate, resulting in light scattering that diminishes absorption of the perovskite layer. In this study, we propose a strategy that combines atomic layer deposition (ALD) and sol-gel solution to deposit a bilayer SnO2 structure to address these issues.

View Article and Find Full Text PDF

Pancreatic cystic changes in adults are increasingly identified through advanced cross-sectional imaging. However, the impact of initial/intra-lobular epithelial remodeling on the local β-cell population remains unclear. In this study, we examined 10 human cadaveric donor pancreases (tail and body regions) via integration of stereomicroscopy, clinical H&E histology, and 3D immunohistochemistry, identifying 36 microcysts (size: 1.

View Article and Find Full Text PDF

Ferroelectric Optical Memristors Enabled by Non-Volatile Electro-Optic Effect.

Adv Mater

January 2025

Institute of Modern Optics & Tianjin Key Laboratory of Micro-Scale Optical Information Science and Technology, Nankai University, Tianjin, 300350, P. R. China.

Memristors enable non-volatile memory and neuromorphic computing. Optical memristors are the fundamental element for programmable photonic integrated circuits due to their high-bandwidth computing, low crosstalk, and minimal power consumption. Here, an optical memristor enabled by a non-volatile electro-optic (EO) effect, where refractive index modulation under zero field is realized by deliberate control of domain alignment in the ferroelectric material Pb(MgNb)O-PbTiO(PMN-PT) is proposed.

View Article and Find Full Text PDF

In this paper, a dual-parameter liquid level and refractive index (R.I.) sensor is fabricated using three pieces of bare polymer optical fibers (POFs), which can independently and simultaneously sense the liquid level and R.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!