Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A new method for the speciation of ng/mL concentrations of Cr(III) and Cr(VI) solutions with analysis by laser-induced breakdown spectroscopy (LIBS) is reported. Speciation is achieved by pre-concentration of the chromium onto commercially available cation exchange polymer membranes. Chromium(III) is removed directly by cation exchange; chromium(VI) in the filtrate is reduced to Cr(III) and concentrated onto a second cation exchange membrane, affording independent measurement of both species. Large volumes of waters containing Cr(III) and Cr(VI) can be concentrated onto the membranes and directly analyzed by laser-induced breakdown spectroscopy. The estimated limit of detection corresponds to 500 ng of Cr on the membrane: if a solution volume of 1 L is used, then the detection limit corresponds to a solution concentration of 0.5 ng/mL. Excellent separation of the chromium species is attained. Results show that overall method efficiencies range from 94-116% and are independent of the matrix. The influence of pH has been measured, and although Cr(VI) converts to Cr(III) in acidic solutions, the total Cr recoveries are not appreciably influenced by pH over the range of natural waters (4 to 9). In addition, speciation was performed in the presence of a number of different cations and showed that the method is robust in many different and complex matrices.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1366/0003702053085061 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!