A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Dose calculation of 142Pr microspheres as a potential treatment for arteriovenous malformations. | LitMetric

Dose calculation of 142Pr microspheres as a potential treatment for arteriovenous malformations.

Phys Med Biol

Department of Nuclear Engineering, Texas A&M University, College Station, TX 77843-3133, USA.

Published: January 2005

Arteriovenous malformation (AVM), especially cryptic AVM, can cause highly variable cerebral neurological defects. Injection of 142Pr microspheres into arteries feeding an AVM in order to simulate radio-embolism has been proposed as a novel treatment method. To investigate optimization of radiation dose to the clinically important arterial wall area, preliminary dosimetric studies have been performed. Monte Carlo calculations were performed for simulated arteries filled with microspheres packed by random packing. Arterial radii from 0.05 mm to 3 mm and microsphere radii from 0.01 mm to 0.7 mm were used in the simulation. For constant arterial size, dose varied significantly with microspheres radius. Inter-arterial effect was also simulated using simplified geometry. For the inter-arterial sites, the dose rate was calculated between two arteries of the same size parallel to each other. The dose increased significantly for large arteries (>1 mm radius) filled with large microspheres (>0.3 mm radius). The dose increase between small arteries (<0.3 mm radius) was not as significant as that between large arteries. Overall results indicate that arterial size and microsphere size significantly affect the dose profile. This factor should be taken into account in future clinical applications.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/50/1/012DOI Listing

Publication Analysis

Top Keywords

142pr microspheres
8
dose
6
microspheres
5
arteries
5
dose calculation
4
calculation 142pr
4
microspheres potential
4
potential treatment
4
treatment arteriovenous
4
arteriovenous malformations
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!