Background: Although group A streptococci (GAS) infections are a major cause of morbidity and mortality, outbreaks of associated pneumonia are rare. We report an outbreak of GAS pneumonia that occurred at a US military training camp.

Methods: Standard epidemiologic and laboratory procedures were used to characterize the outbreak and causative organism(s). A case-control study and determination of the prevalence of GAS infection among camp personnel were also performed.

Results: A total of 162 of 4500 Marine Corps personnel were hospitalized for respiratory symptoms during the period of 1 November and 20 December 2002, and 127 (78%) had radiographically confirmed pneumonia. The attack rate was 1.6 cases per 100 person-months. Thirty-four (27%) of 127 patients with pneumonitis had definite or probable GAS pneumonia; an additional 22 (17.3%) were coinfected with GAS and another pathogen. Pathogens, in addition to GAS, included Chlamydia pneumoniae (27 patients), Mycoplasma pneumoniae (19), adenovirus (5), and Streptococcus pneumoniae (2). A survey revealed that the pharyngeal carriage rate of GAS among camp personnel was 16%. Molecular characterization of the GAS isolates found emm type 3, multilocus sequence type 15. The epidemic ended after administration of additional prophylaxis with a single dose of intramuscular benzathine penicillin (1.2 million U) or azithromycin (1 g orally). Because the number of days from the last penicillin injection was correlated with a positive throat culture result and the occurrence of pneumonia, the dosing interval of benzathine penicillin was shortened from every 28-35 days to every 21 days.

Conclusions: This is the largest outbreak of GAS pneumonia reported in >30 years. This outbreak emphasizes the potential for GAS to cause epidemics of severe infection and demonstrates the need for surveillance and consideration of appropriate antibiotic prophylaxis among particularly high-risk populations.

Download full-text PDF

Source
http://dx.doi.org/10.1086/427502DOI Listing

Publication Analysis

Top Keywords

gas pneumonia
12
gas
10
military training
8
outbreak gas
8
camp personnel
8
benzathine penicillin
8
pneumonia
7
pneumonia outbreak
4
outbreak associated
4
associated group
4

Similar Publications

Introduction: This study aimed to analyze the levels of MMP-9 and TIMP-1 as biomarkers for identifying lung anatomical and functional abnormalities in coronavirus disease 2019 (COVID-19).

Methodology: Adult COVID-19 patients hospitalized between October and December 2021 were included in the study. MMP-9 and TIMP-1 levels were measured from the blood.

View Article and Find Full Text PDF

High-Performance Polyolefin Material: Synthesis, Properties, and Application of Poly(4-Methyl-1-pentene).

Int J Mol Sci

January 2025

School of Materials Science and Engineering, PCFM Lab, GD HPPC Lab, Sun Yat-sen University, Guangzhou 510275, China.

As a kind of high-performance thermoplastic crystalline resin, poly(4-methyl-1-pentene) (PMP) is characterized by its low density, low dielectric constant, exceptional mechanical and chemical properties, high transparency, and gas permeability. PMP has recently received more attention since COVID-19, because it is used as a hollow-fiber membrane for extracorporeal membrane oxygenation (ECMO) based on its high permeability and excellent biocompatibility. This review summarizes the chemical structure, synthesis, properties, and application of PMP.

View Article and Find Full Text PDF

Background: Papaya leaves (PLs) are known for their therapeutic benefits and traditional use in treating inflammation, infections, and various health conditions. Rich in bioactive compounds, PLs are studied for their potential applications in functional foods. This study analyzed their nutritional, phytochemical, structural, thermal, and antimicrobial properties to evaluate their role as a health-promoting ingredient.

View Article and Find Full Text PDF

Smart oxygen monitoring in hospitals: a pilot study during COVID-19.

Sci Rep

January 2025

Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 70800, Ostrava, Czech Republic.

During 2020-2021, the COVID-19 pandemic exposed significant vulnerabilities in hospital safety, with oxygen-related fires and explosions occurring at twice the usual rate. This highlighted insufficient preparedness for increased oxygen therapy demands and the associated risks of oxygen-enriched atmospheres. This study aimed to develop and test a smart monitoring system to detect increased oxygen concentrations in hospital environments, mitigating the risk of fires.

View Article and Find Full Text PDF

New Diagnostics for Fungal Infections in Transplant Infectious Disease: A Systematic Review.

J Fungi (Basel)

January 2025

Division of Infectious Disease, Department of Medicine, Keck School of Medicine, University of Southern California, 1500 San Pablo St., Los Angeles, CA 90033, USA.

Fungal infections are common in highly immunosuppressed, solid organ transplant recipients. They can be quite difficult to diagnose in a timely manner; thus, we present a review of current studies focusing on broad categories of molecular diagnostics, i.e.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!