Intensity-modulated arc therapy for treatment of high-risk endometrial malignancies.

Int J Radiat Oncol Biol Phys

Department of Oncology, University of Western Ontario, and London Regional Cancer Centre, 790 Commissioners Road East, London, Ontario N6A 4L6, Canada.

Published: March 2005

Purpose: We developed an intensity-modulated arc therapy (IMAT) technique for the treatment of women with high-risk endometrial malignancies. In the context of multimodality therapy, nodal and tumor bed irradiation was delivered while respecting tolerance doses for critical structures.

Methods And Materials: Five patients were planned and treated with the IMAT technique after hysterectomy. Computed tomographic (CT) scans for treatment planning were acquired with the tumor bed contoured as the clinical target volume (CTV(tumor_bed)) and the iliac and presacral vessels contoured as the gross tumor volume (GTV). In 2 patients the lower para-aortic nodes were included into the GTV. The small bowel, iliac crests, femoral heads, bladder, and rectum were contoured as critical organs. For the nodes, a CTV(nodes) was generated with a 7-10-mm margin around the vessels, and the planning target volume (PTV(nodes)) was generated by a further 5-mm expansion. For the tumor bed, the PTV(tumor_bed) was generated with a margin of 7-10 mm around CTV(tumor_bed). Planning constraints included adequate coverage of the tumor bed (>95% receiving > or =45 Gy) and nodes (> or =95% receiving > or =40 Gy). Arc combinations with different extents were tested, and the final plan was generated based on the balance between complexity (number of arcs), PTV coverage, and critical structure sparing. Conventional and 8-field intensity-modulated radiation therapy (IMRT) plans were generated for each patient for comparison purposes. All patients were treated with IMAT.

Results: We found that two anterior intensity-modulated arcs (300 degrees to 30 degrees and 330 degrees to 60 degrees ) adequately treated the PTVs. Furthermore, this IMAT technique allowed sparing of small bowel and the iliac crests (marrow space) to a similar degree as the 8-field IMRT. The 8-field IMRT yielded better dose uniformity than IMAT in the target volumes; however, neither technique was as uniform as the conventional plan. In the 5 patients, IMAT treatment was well tolerated and completed as planned.

Conclusions: We successfully piloted an optimized intensity-modulated arc technique to treat 5 high-risk endometrial cancer patients undergoing multimodality treatment. This allowed a significant reduction in dose to bone marrow and small bowel compared with conventional techniques and was simpler to deliver than multifield IMRT.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijrobp.2004.06.253DOI Listing

Publication Analysis

Top Keywords

tumor bed
16
intensity-modulated arc
12
high-risk endometrial
12
imat technique
12
small bowel
12
arc therapy
8
endometrial malignancies
8
target volume
8
bowel iliac
8
iliac crests
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!