Objectives: To evaluate the impact on lipid and carbohydrate variables of a combined one-third ethinyl estradiol (EE)/levonorgestrel (LNG) dose reduction in oral contraceptives.
Methods: In an open-label, randomized study, a dose-reduced oral contraceptive containing 20 microg EE and 100 microg LNG (20 EE/100 LNG) was compared with a reference preparation containing 30 microg EE and 150 microg LNG (30 EE/150 LNG). One-year data from 48 volunteers were obtained.
Results: We found a decrease of HDL2 cholesterol and increases of low-density lipoprotein cholesterol, very low-density lipoprotein cholesterol and total triglycerides in both treatment groups from baseline to the 13th treatment cycle. Although for four of six variables, the changes in the 20 EE group were lower compared with the 30 EE group, none of the differences between the two treatments were statistically significant. The median values for the fasting levels of insulin, C-peptide and free fatty acids slightly increased or remained unchanged while the fasting glucose levels slightly decreased after 13 treatment cycles. While the glucose area under the curve (AUC) (0-3 h) was similar in both groups during the OGTT, the insulin AUC(0-3 h) was less increased in the 20 EE/100 LNG group compared with the 30 EE/150 LNG group. None of the differences between the treatment groups for any of the carbohydrate metabolism variables were statistically significant at any time point. Both study treatments were safe and well tolerated by the volunteers.
Conclusion: Similar effects on the lipid and carbohydrate profiles were found for both preparations. The balanced one-third EE dose reduction in this new oral contraceptive caused slightly lower, but insignificant, changes in the lipid and carbohydrate variables compared with the reference treatment.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.contraception.2004.08.017 | DOI Listing |
Invest Radiol
October 2024
From the Institute for Diagnostic and Interventional Radiology, University Hospital Zurich, University Zurich, Zurich, Switzerland (B.K., F.E., J.K., T.F., L.J.); Advanced Radiology Center, Department of Diagnostic Imaging and Oncological Radiotherapy, Fondazione Policlinico Universitario "A. Gemelli" IRCCS, Rome, Italy (C.S., A.R.L.); and Section of Radiology, Department of Radiological and Hematological Sciences, Università Cattolica del Sacro Cuore, Rome, Italy (A.R.L.).
Objectives: The aim of this study was to evaluate the feasibility and efficacy of visual scoring, low-attenuation volume (LAV), and deep learning methods for estimating emphysema extent in x-ray dose photon-counting detector computed tomography (PCD-CT), aiming to explore future dose reduction potentials.
Methods: One hundred one prospectively enrolled patients underwent noncontrast low- and chest x-ray dose CT scans in the same study using PCD-CT. Overall image quality, sharpness, and noise, as well as visual emphysema pattern (no, trace, mild, moderate, confluent, and advanced destructive emphysema; as defined by the Fleischner Society), were independently assessed by 2 experienced radiologists for low- and x-ray dose images, followed by an expert consensus read.
Med Phys
December 2024
Department of Physics, Lakehead University, Thunder Bay, Ontario, Canada.
Background: This study investigates a multi-angle acquisition method aimed at improving image quality in organ-targeted PET detectors with planar detector heads. Organ-targeted PET technologies have emerged to address limitations of conventional whole-body PET/CT systems, such as restricted axial field-of-view (AFOV), limited spatial resolution, and high radiation exposure associated with PET procedures. The AFOV in organ-targeted PET can be adjusted to the organ of interest, minimizing unwanted signals from other parts of the body, thus improving signal collection efficiency and reducing the dose of administered radiotracer.
View Article and Find Full Text PDFPLoS One
December 2024
Chair of Biomedical Physics, Department of Physics & School of Natural Sciences, Technical University of Munich, Garching bei München, Germany.
Background: Dark-field radiography has been proven to be a promising tool for the assessment of various lung diseases.
Purpose: To evaluate the potential of dose reduction in dark-field chest radiography for the detection of the Coronavirus SARS-CoV-2 (COVID-19) pneumonia.
Materials And Methods: Patients aged at least 18 years with a medically indicated chest computed tomography scan (CT scan) were screened for participation in a prospective study between October 2018 and December 2020.
Synapse
January 2025
Department of Science, De La Salle College, Institute of the Brothers of the Christian Schools, Toronto, Ontario, Canada.
Alcohol consumption is known to affect dopamine (DA) release in the brain, with significant implications for understanding addiction and its neurobiological underpinnings. This meta-analysis examined the effects of acute alcohol administration on striatal DA release in healthy humans as measured with [C]-raclopride positron emission tomography (PET). Oral alcohol administration was associated with a significant reduction in [C]-raclopride binding potential (BP) in the ventral striatum (Cohen's d = -0.
View Article and Find Full Text PDFJ Funct Biomater
December 2024
Institute of Theoretical and Experimental Biophysics, Russian Academy of Sciences, Pushchino 142290, Russia.
X-ray-induced photodynamic therapy (X-PDT) represents a promising new method of cancer treatment. A novel type of nanoscintillator based on cerium fluoride (CeF) nanoparticles (NPs) modified with flavin mononucleotide (FMN) has been proposed. A method for synthesizing CeF-FMN NPs has been developed, enabling the production of colloidal, spherical NPs with an approximate diameter of 100 nm, low polydispersity, and a high fluorescence quantum yield of 0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!