Shear bond strength of Bis-GMA resin and methacrylated dendrimer resins on silanized titanium substrate.

Dent Mater

Department of Prosthetic Dentistry and Biomaterials Research, Institute of Dentistry, University of Turku, Lemminkäisenkatu 2, FI-20520 Turku, Finland.

Published: March 2005

Objectives: The study compared the bond strengths of three resins, Bis-GMA and two novel experimental methacrylated polyester dendrimer resins to grit-blasted titanium substrate with three silanes.

Methods: Two commercial dental silanes (ESPE Sil and Monobond-S) and an experimental 0.5 vol% 3-methacryloxypropyltrimethoxysilane were applied to grit-blasted Ti substrates. Light-polymerizable resins of Bis-GMA and methacrylated dendrimer were applied to the grit-blasted Ti substrate with polyethylene molds. The substrates with resin stubs (n = 10) were thermocycled (6000 cycles, 5-55 degrees C) or kept in water (37 degrees C, 24 h). The shear bond strength of the resin was measured at a crosshead speed of 1.0 mm min(-1). The surface examination, before and after silanization, was made with a scanning electron microscope (SEM). The silane reactions on the Ti surface were monitored by Fourier transform infrared spectrometry.

Results: Statistical analysis (ANOVA) showed that the highest shear bond for thermocycled samples was obtained for Bis-GMA with Monobond-S (19.4 MPa, standard deviation (SD) 7.1 MPa), and after water storage with a laboratory-made silane (26.4 MPa, SD 8.1 MPa). The dendrimer and Bis-GMA resins conferred equal bonding properties to grit-blasted titanium after thermocycling. The silane, resin type, and storage conditions significantly affected the shear bond strength (p < 0.001 for all factors). SEM images suggested a mainly cohesive type of bonding failure.

Significance: A dendrimer based resin and the Bis-GMA resin systems conferred statistically equivalent bonding properties to silica-coated Ti after thermocycling.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.dental.2004.03.011DOI Listing

Publication Analysis

Top Keywords

shear bond
16
bond strength
12
bis-gma resin
8
methacrylated dendrimer
8
dendrimer resins
8
titanium substrate
8
resins bis-gma
8
grit-blasted titanium
8
applied grit-blasted
8
bonding properties
8

Similar Publications

Purpose: This study investigated the effects of femtosecond laser (FL) irradiation on the surface roughness and shear bond strength of high-translucency zirconia (6 mol% yttria-partially stabilized zirconia [6Y-PSZ]) and lithium disilicate (LiSiO) glass ceramics.

Methods: Fully sintered square-shaped specimens of 6Y-PSZ (7 groups; 20 specimens/group) and LiSiO (8 groups; 20 specimens/group) were surface-treated via sandblasting (50-μm alumina sand or glass beads) or FL irradiation (20- or 40-μm dot or cross-line patterns) or using Monobond Etch & Prime (Ivoclar Vivadent AG; only for LiSiO specimens). The surface roughness (arithmetic average [Sa] and developed interfacial area ratio [Sdr]) and shear bond strength after 24 h and 10,000 thermal cycles were measured and statistically analyzed.

View Article and Find Full Text PDF

In response to the rotary ploughing equipment in the stubble land to implement protective operations, the stubble is large in number and strong in toughness, not easy to crush, resulting in rotary ploughing equipment to produce entanglement and increased resistance to rotary ploughing and other issues. In this study, researchers designed a bionic rotary tillage blade (B-RTB) based on the bionic structural equations of the Marmota claw. A straw-soil complex shear performance test was conducted to investigate the effect of straw on soil shear strength.

View Article and Find Full Text PDF

Statement Of Problem: Comprehensive data are needed on the performance of chemically activated, chairside hard reline materials when used with computer-aided design and computer-aided manufacturing (CAD-CAM) milled polymethyl methacrylate (PMMA) denture bases and conventionally processed bases. This lack of data affects decisions regarding the chairside reline material to be used for improving the fit and retention of relined complete dentures.

Purpose: The purpose of this in vitro study was to evaluate and compare the shear bond strength (SBS) of 3 chemically activated, chairside hard reline materials on CAD-CAM milled and conventional heat-polymerized PMMA denture bases.

View Article and Find Full Text PDF

Objectives: To evaluate the shear bond strength (SBS) of universal cements (UCs) to dentin prepared with different diamond burs using various adhesive strategies.

Materials And Methods: One-hundred-twenty molars were prepared to expose the mid-coronal dentin. The teeth were divided into two groups according to diamond bur preparations: coarse and super-fine grit burs.

View Article and Find Full Text PDF

Objectives:  Orthodontic bracket bond failure is an obstacle in clinical orthodontics. This study investigated the influence of pH cycling on the shear bond strength (SBS), adhesive remnant index (ARI), and survival probability of adhesive-precoated flash-free ceramic brackets.

Materials And Methods:  Forty mandibular premolars were randomly divided into two groups ( = 20): C: noncoated orthodontic brackets, and F: flash-free adhesive-precoated orthodontic brackets.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!