Is the tracer velocity of a fluid continuum equal to its mass velocity?

Phys Rev E Stat Nonlin Soft Matter Phys

Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139-4307, USA.

Published: December 2004

Owing to its size independence in the so-called near-continuum vanishingly small Knudsen number regime (Kn<<1) , thermophoretic particle motion occurring in an otherwise quiescent gas under the influence of a temperature gradient is here interpreted as representing the motion of a tracer, namely, an effectively point-size test particle monitoring the local velocity of the undisturbed, particle-free, compressible gas continuum through space. "Compressibility" refers here not to the usual effect of pressure on the gas's mass density rho but rather to the effect thereon of temperature. Our unorthodox continuum interpretation of thermophoresis differs from the usual one, which regards the existence of thermophoretic forces in gases as a strictly noncontinuum phenomenon, involving thermal stress-induced Maxwell slip ("thermal creep") of the gas's mass velocity vm at the surface of the particle, with vm denoting the velocity appearing in the continuity equation expressing the law of conservation of mass. Explicitly, instead of regarding the thermally animated particle as moving through the gas, we regard the particle (in its hypothesized role as a tracer of the undisturbed, particle-free, fluid motion) as moving with the gas, through space; that is, the particle is viewed as simply being entrained in the flowing gas, which, as a result of an externally applied temperature gradient, was already in motion prior to the tracer's introduction into the fluid--albeit not mass motion (which is, in fact, identically zero) but rather volume motion. This tracer-particle interpretation of experimental thermophoretic particle velocity measurements raises fundamental issues in regard to the universally accepted Newtonian rheological law constitutively specifying the viscous or deviatoric stress T as being proportional to the (symmetrized, traceless) fluid velocity gradient inverted Deltav , with v identified as being the fluid's mass velocity vm . Rather, it is argued in the case of compressible fluids, including liquids, that v should, instead, be chosen as the fluid's volume flux density or current density nv , the latter being formally equivalent to the fluid's volume velocity vv , which differs from vm except in the case of incompressible fluids. Apart from this strictly constitutive issue in regard to T , it is further argued that the fluid's tracer or Lagrangian velocity vl:=(deltax/deltat) (x0) along the fluid's spatiotemporal trajectory x=x (x0,t) is equal to vv, rather than to vm. This too is contrary to the heretofore unquestioned supposition that the conceptually distinct fluid velocities vl and vm are not only equal but are, in fact, synonymous. To the extent that vl not equal vm in the nonisothermal fluid case, an optical dye- or photochromic-type experiment (each of the latter two experiments presumably serving to measure vm) will record a different velocity than would a comparable tracer particle velocity measurement, one that measures vl .

Download full-text PDF

Source
http://dx.doi.org/10.1103/PhysRevE.70.061201DOI Listing

Publication Analysis

Top Keywords

tracer velocity
4
velocity fluid
4
fluid continuum
4
continuum equal
4
equal mass
4
mass velocity?
4
velocity? size
4
size independence
4
independence so-called
4
so-called near-continuum
4

Similar Publications

Density-dependent flow generation in active cytoskeletal fluids.

Sci Rep

December 2024

Department of Chemical Engineering, Kyoto University, Nishi-kyoku, Kyoto, 615-8510, Japan.

Article Synopsis
  • The actomyosin cytoskeleton, made up of actin fibers and myosin motors, creates contractile forces that influence various cellular movements, but its density-related behaviors are not well understood.
  • By adjusting the concentration of actomyosin cell extracts, researchers found that in cell-sized droplets, actin flows toward the center at a critical density, creating oscillatory motion.
  • The study suggests that changes in myosin activity can disrupt regular oscillatory flows, indicating that the dynamics of actomyosin flow are influenced by the balance between actin density and myosin forces.
View Article and Find Full Text PDF

Laminar Fluid Ejection for Olfactory Drug Delivery: A Proof of Concept Study.

IEEE J Transl Eng Health Med

December 2024

Rocket Science Health Victoria BC V8V 2Y1 Canada.

Focal intranasal drug delivery to the olfactory cleft is a promising avenue for pharmaceuticals targeting the brain. However, traditional nasal sprays often fail to deliver enough medication to this specific area. We present a laminar fluid ejection (LFE) method for precise delivery of medications to the olfactory cleft.

View Article and Find Full Text PDF

Sedimentation tanks represent one of the most important components of any water and wastewater treatment plants. The lack of knowledge of hydraulics in sedimentation tank leads to unnecessary capital and operating costs as well as water pollution in the form of excessive sludge. Improper and inadequate design cause overloading of filters, and lead to frequent backwashing, which in turn waste a significant percentage of treated water.

View Article and Find Full Text PDF

At-a-station hydraulic geometry (AASHG) relationships describe the dependence of a river's width, mean depth and mean velocity on discharge at a given location, and are typically modelled as power-law functions. They are often used when modelling stream temperature under unsteady flow conditions. Deriving AASHG relationships is challenging for steep proglacial streams due to the combination of complex morphology and velocity distributions, and rapidly varying flow.

View Article and Find Full Text PDF

Influence of kinetic air-water interfacial partitioning on unsaturated transport of PFAS in sandy soils.

Sci Total Environ

December 2024

Civil & Environmental Engineering Department, Hydrologic Science and Engineering Program, Hydrologic Science & Engineering Program, ReNuWit-The Urban Water Engineering Research Center, Colorado School of Mines, Golden, CO 80401, USA. Electronic address:

Article Synopsis
  • - This study explores how kinetic air-water partitioning influences the movement of PFAS (perfluoroalkyl substances) in sandy soil, particularly under dynamic unsaturated flow situations.
  • - Short-chain PFAS act like conservative tracers with minimal partitioning, whereas longer-chain PFAS show non-equilibrium behavior, and the presence of air-water interfaces significantly affects their transport.
  • - The research highlights that considering kinetic partitioning processes can more than double the mass flux of PFOS to groundwater, indicating a major impact on PFAS concentrations in porewater.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!