Erythrocyte-associated transients in PO2 revealed in capillaries of rat mesentery.

Am J Physiol Heart Circ Physiol

Dept. of Physiology, Medical College of Virginia Campus, Virginia Commonwealth Univ., 1101 E. Marshall St., PO Box 980551, Richmond, VA 23298-0551, USA.

Published: June 2005

Mathematical models have predicted the existence of Po(2) gradients between erythrocytes in capillaries in the usual case where plasma contributes substantial resistance to oxygen diffusion. According to theoretical predictions, these gradients could be detected as rapid Po(2) fluctuations (erythrocyte-associated transients, EATs) along the capillary. However, verification of a model and correct choice of its parameters can be made only on the basis of direct experimental measurements. We used phosphorescence quenching microscopy to measure Po(2) in 52 capillaries of rat mesentery to obtain plasma Po(2) values 100 times/s at a given point along a capillary. A 532-nm laser generated 10-micros pulses of light, concentrated by a x100 objective, onto a spot 0.9 microm in diameter. The presence of erythrocytes in the excitation region was detected on the basis of phosphorescence amplitude (PA), proportional to the amount of plasma encountered by the laser beam, and on the basis of the intensity of transmitted laser light (LT), detected by a photodiode placed under the capillary. The data revealed correlated waveforms in PA, LT, and Po(2) in capillaries. The magnitude of the Po(2) gradients between erythrocytes and plasma was correlated with average capillary Po(2). EATs in Po(2) were more readily detected in capillaries with relatively low oxygenation. The correlation coefficients between PA and Po(2) for the half of the capillaries (n = 26) below the median Po(2) (mean Po(2) = 17 mmHg; R = -0.72) was higher than that for the other half (mean Po(2) = 39 mmHg; R = -0.38). These results support the theoretical predictions of EATs and plasma Po(2) gradients in capillaries.

Download full-text PDF

Source
http://dx.doi.org/10.1152/ajpheart.00711.2004DOI Listing

Publication Analysis

Top Keywords

po2
14
po2 gradients
12
erythrocyte-associated transients
8
capillaries rat
8
rat mesentery
8
gradients erythrocytes
8
theoretical predictions
8
po2 capillaries
8
plasma po2
8
po2 mmhg
8

Similar Publications

Hyperbaric oxygen therapy (HBOT) is a non-invasive method of O2 delivery that induces systemic hyperoxia. Hyperbaric chamber consists of a pressure vessel and a compressed breathing gas supply, which can regulate internal pressure. The chamber delivers 100% O2 to patients according to predetermined protocols and is monitored by trained personnel.

View Article and Find Full Text PDF

Purpose: Solid crystalline spin probes, such as lithium phthalocyanine (LiPc) and lithium octa-n-butoxynaphthalocyanine (LiNc-BuO), allow repeated oxygen measurement using electron paramagnetic resonance (EPR). Due to their short relaxation times, their use for pulse EPR oxygen imaging is limited. In this study, we developed and tested a new class of solid composite spin probes that modified the relaxation rates R and R of LiPc or LiNc-BuO probes, which allowed pO measurements in the full dynamic (0-760 torr) range.

View Article and Find Full Text PDF

Arieli has previously demonstrated that the exposure metric K could be used to predict pulmonary oxygen toxicity (POT) based on changes in Vital Capacity (VC). Our previous findings indicate that the Equivalent Surface Oxygen Time (ESOT) allows the estimation of POT without loss of accuracy compared to K. In this work, we have further investigated POT recovery.

View Article and Find Full Text PDF

Out-of-focus signal rejection for pO measurements using two-photon phosphorescence lifetime microscopy.

Biomed Opt Express

January 2025

Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Charlestown, MA 02129, USA.

Two-photon phosphorescence lifetime microscopy has been a key tool for studying cerebral oxygenation in mice. However, the accuracy of the partial pressure of oxygen (pO) measurements is affected by out-of-focus signal. In this work, we applied reconfigurable differential aberration imaging to characterize and correct for out-of-focus signal contamination in intravascular pO imaging.

View Article and Find Full Text PDF

CLIPA protein pairs function as cofactors for prophenoloxidase activation in Anopheles gambiae.

Insect Biochem Mol Biol

January 2025

Department of Entomology and Plant Pathology, Oklahoma State University, Stillwater, OK, 74078, USA. Electronic address:

Insect prophenoloxidases (proPO) are activated during immune responses by a proPO activating protease (PAP) in the presence of a high molecular weight cofactor assembled from serine protease homologs (SPH) that lack proteolytic activity. PAPs and the SPHs have a similar architecture, with an amino-terminal clip domain and a carboxyl-terminal protease domain. The SPHs belong to CLIPA subfamily of SP-related proteins.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!