A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Simultaneous determination of trans, transmuconic acid and s-phenylmercapturic acid by high pressure liquid chromatography and its application. | LitMetric

Simultaneous determination of trans, transmuconic acid and s-phenylmercapturic acid by high pressure liquid chromatography and its application.

Southeast Asian J Trop Med Public Health

Department of Social and Environmental Medicine, Faculty of Tropical Medicine, Mahidol University, Bangkok, Thailand.

Published: September 2004

The simultaneous determination of urinary trans,trans-muconic acid (t,t-MA) and S-phenylmercapturic acid (S-PMA) was performed by liquid extraction with ethyl acetate and reversed-phase high performance liquid chromatography (RP-HPLC) on a Hypersil-ODS column using the gradient mobile phase of methanol and 0.0012 N perchloric acid and diode array detection at 205 and 264 nm for S-PMA and t,t-MA, respectively. The retention times for t,t-MA and S-PMA were 3.8 and 12.3 minutes, respectively. The recoveries of t,t-MA and S-PMA were > 97%; between-day precisions were all within 8% RSD (100x SD/mean). The method was applied to analyze the urinary t,t-MA and S-PMA of 59 service station attendants exposed to average benzene concentrations in the air of 0.20+/-0.18 ppm. Significant differences in pre-shift and post-shift urinary t,t-MA between smokers and non-smokers were found.

Download full-text PDF

Source

Publication Analysis

Top Keywords

tt-ma s-pma
12
simultaneous determination
8
s-phenylmercapturic acid
8
liquid chromatography
8
urinary tt-ma
8
tt-ma
6
acid
5
s-pma
5
determination trans
4
trans transmuconic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!