Valsartan versus ACE inhibition after bare metal stent implantation--results of the VALVACE trial.

Int J Cardiol

Department of Cardiology, Academic Teaching Hospital of Quedlinburg, University of Magdeburg, Germany.

Published: February 2005

The use of ACE inhibitors (ACE-i) represents an Ia recommendation in the treatment of patients with STEMI and NSTEMI. However, results of smaller studies suggest an increase of in-stent-restenosis under ACE-i administration. The effects of ACE-i and valsartan after bare metal stent implantation of the culprit type B2/C lesion should be compared. Seven hundred patients were treated either by ACE-i in cases of LVEF<50% or 80 mg valsartan in cases of LVEF> or =50%. Restenosis rates after 6 months were analysed in 399 patients under valsartan and 224 patients under ACE-i with control angiography and major adverse cardiac events (death, infarction, reintervention) in a follow-up of up to 4 (mean 2.6) years in all patients. In-stent-restenosis was found in 19.5% under valsartan and in 34% under ACE-i (p<0.005). In diabetic patients, restenosis occurred in 24% under valsartan and in 43% under ACE-i (p<0.01). In initial acute coronary syndrome (ACS), restenosis rate was 14% under valsartan and 43% under ACE-i (p<0.0001). In stable angina, restenosis rates were 26.5% and 27.5%, respectively. Total MACE rates revealed significant differences in ACS due to reintervention rates of 22% and 7% under ACE-i and valsartan (p<0.0001). The administration of 80 mg valsartan after bare metal stent implantation leads to a reduction of in-stent-restenosis compared to ACE-i. This effect is mainly due to beneficial effects of valsartan in cases with initial ACS. Major differences between ACE-i and valsartan are discussed including inflammation, activation of neutrophils, mode of bradykinin activation, AT2 receptor stimulation and apoptosis of smooth muscle cells.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijcard.2004.05.062DOI Listing

Publication Analysis

Top Keywords

bare metal
8
metal stent
8
ace-i
6
patients
5
valsartan
4
valsartan versus
4
versus ace
4
ace inhibition
4
inhibition bare
4
stent implantation--results
4

Similar Publications

Engineering conductive covalent-organic frameworks enable highly sensitive and anti-interference molecularly imprinted electrochemical biosensor.

Biosens Bioelectron

January 2025

Key Laboratory of Molecular Medicine and Biotherapy, the Ministry of Industry and Information Technology, School of Life Science, Beijing Institute of Technology, Beijing, 100081, China. Electronic address:

Covalent organic frameworks (COFs) have drawn great interest in electrochemical sensing. However, most are integrated as enrichment units or reaction carriers and are co-modified with metal nanomaterials. Few studies use the single pristine COFs as an electrochemical signal amplifier.

View Article and Find Full Text PDF

Electronic coupling between individual redox units in a molecular assembly dictates their charge transfer efficacy. Being a well-defined crystalline structure, the metal-organic framework (MOF) ensures proper positioning of redox-active moieties and provides a unique platform to unveil their charge transfer dynamics and quantification with structural relationships. Here, we demonstrate a novel redox-active MOF with near-infrared through-space intervalence charge transfer by introducing a mixed valence state inside redox-active thiazolothiazole-based ligands (DPTTZ) upon photo- or electrochemical reduction.

View Article and Find Full Text PDF

Biodegradable Stents in the Treatment of Arterial Stenosis.

J Clin Med

January 2025

Department of Accident and Emergency, Etlik City Hospital, Ankara 06170, Turkey.

Arterial diseases (ADs) are a significant health problem, with high mortality and morbidity rates. Endovascular interventions, such as balloon angioplasty (BA), bare-metal stents (BMSs), drug-eluting stents (DESs) and drug-coated balloons (DCBs), have made significant progress in their treatments. However, the issue has not been fully resolved, with restenosis remaining a major concern.

View Article and Find Full Text PDF

The unique redox properties of nanoscale cerium dioxide determine its diverse application in biology and medicine as a regulator of oxidative metabolism. Lipid modifiers of the nanoparticle surface change their biochemical properties and bioavailability. Complexes with lipids can be formed upon contact of the nanoparticles with the membrane.

View Article and Find Full Text PDF

Objective: it was to evaluate the efficacy and safety of rapamycin-eluting stents at different doses in the treatment of coronary artery narrowing in miniature pigs.

Methods: a total of 20 miniature pigs were randomly assigned into four groups: S1 group (low-dose rapamycin-coated stent, 55 µg/mm), S2 group (medium-dose rapamycin-coated stent, 120 µg/mm), S3 group (high-dose rapamycin-coated stent, 415 µg/mm), and D0 group (bare metal stent). The stent size was 3.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!