Objective: We sought to assess the rabbit as an experimental animal in the investigation of laser skin soldering. We studied, using the scanning electron microscope (SEM), the surface appearances of experimental incisions made on the rabbit back skin and soldered by CO(2) laser.
Background Data: Laser soldering of incisions in various tissues is a modality of wound healing of a very promising clinical value. At present, more component studies on animals directed at paving the way towards clinical protocols are needed.
Methods: Surgical incisions on rabbits back skin were bonded using either albumin-assisted CO(2) laser soldering (experimental) or thread suturing (reference). The incisions closed were excised 2, 3, 4, and 5 days postoperatively, and skin surfaces were studied in the SEM.
Results: Naked eye inspection and SEM analysis showed that full-length sealing of soldered and sutured incisions was discernible as early as day 2. In the SEM, all incisions were found confluently coated by epidermal cells along the former cut streak. Soldering subserved to bond incisions efficiently, with surface smooth and close to normal skin. On the other hand, the surface of sutured incisions appeared convoluted and its aesthetic quality inferior to that of the former. Some of the days two and three soldered incisions suffered dehiscence on excision, which suggests an incomplete regeneration of tensile strength at this early phase of healing. Sutured incisions tolerated excision, very probably due to the microthread still present in the skin tissue rather than because of breaking strength regained during wound healing. Also, hair stumps re-grown on the skin by day 5 postoperative might impair satisfactory microscopy of bonded incisions.
Conclusions: CO(2) laser soldering of incisions on the rabbit back skin effected rapid wound sealing and resulted in smooth scars indistinguishable from normal skin. The rabbit is well suited for this kind of studies, provided that excision of experimental cuts takes place not later than 5 days post-incision so that hair stumps may not grow large enough to jeopardize the quality of scanning electron microscopy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1089/pho.2004.22.461 | DOI Listing |
ACS Biomater Sci Eng
January 2025
Advanced Materials Department, Jožef Stefan Institute, 1000 Ljubljana, Slovenia.
Characterization and formation of the biomineral aragonite structures of the Noah's Ark shell ( L.,1758) were studied from structural, morphogenetic, and biochemical points of view. Structural and morphological features were examined using X-ray diffraction, field-emission scanning electron microscopy, and atomic force microscopy, while thermal properties were determined by thermogravimetric and differential thermal analyses.
View Article and Find Full Text PDFJ Med Microbiol
January 2025
Institute of Advanced Study in Science and Technology (IASST), Guwahati 781035, Assam, India.
Cold atmospheric plasma (CAP) has emerged as a promising technology for neutralizing microbes, including multidrug-resistant strains. This study investigates CAP's potential as an alternative to traditional antimicrobial drugs for microbial inactivation. In the era of increasing antimicrobial resistance, there is a persistent need for alternative antimicrobial strategies.
View Article and Find Full Text PDFACS Appl Bio Mater
January 2025
Departamento de Física, Universidade Federal de Viçosa, Viçosa, Minas Gerais 36570-900, Brasil.
This study investigates the functionalization of gold-coated magnetoelastic sensors with thionine molecules, focusing on resonance frequency shifts. The functionalization process was characterized by using Raman spectroscopy and analyzed via scanning electron microscopy and atomic force microscopy, revealing the progressive formation of molecular clusters over time. Our results demonstrate that longer functionalization time leads to saturation of surface coverage and cluster formation, impacting the sensor's resonance frequency shifts.
View Article and Find Full Text PDFPhys Rev Lett
December 2024
Massachusetts Institute of Technology, Research Laboratory of Electronics, Cambridge, Massachusetts 02139, USA.
Classical transport of electrons and holes in nanoscale devices leads to heating that severely limits performance, reliability, and efficiency. In contrast, recent theory suggests that interband quantum tunneling and subsequent thermalization of carriers with the lattice results in local cooling of devices. However, internal cooling in nanoscale devices is largely unexplored.
View Article and Find Full Text PDFPhys Rev Lett
December 2024
Brookhaven National Laboratory, Condensed Matter Physics and Materials Science Division, Upton, New York 11973, USA.
We present a protocol for detecting multipartite entanglement in itinerant many-body electronic systems using single-particle Green's functions. To achieve this, we first establish a connection between the quantum Fisher information and single-particle Green's functions by constructing a set of witness operators built out of single electron creation and destruction operators in a doubled system. This set of witness operators is indexed by a momentum k.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!