Transceive array coils, capable of RF transmission and independent signal reception, were developed for parallel, 1H imaging applications in the human head at 7 T (300 MHz). The coils combine the advantages of high-frequency properties of transmission lines with classic MR coil design. Because of the short wavelength at the 1H frequency at 300 MHz, these coils were straightforward to build and decouple. The sensitivity profiles of individual coils were highly asymmetric, as expected at this high frequency; however, the summed images from all coils were relatively uniform over the whole brain. Data were obtained with four- and eight-channel transceive arrays built using a loop configuration and compared to arrays built from straight stripline transmission lines. With both the four- and the eight-channel arrays, parallel imaging with sensitivity encoding with high reduction numbers was feasible at 7 T in the human head. A one-dimensional reduction factor of 4 was robustly achieved with an average g value of 1.25 with the eight-channel transmit/receive coils.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.20321DOI Listing

Publication Analysis

Top Keywords

parallel imaging
12
human head
8
300 mhz
8
mhz coils
8
transmission lines
8
four- eight-channel
8
arrays built
8
coils
6
transmit receive
4
transmission
4

Similar Publications

Background: Cigarette smoking is a leading cause of death and disease, including those related to the cardiovascular system. Cytisine is a plant-based medication, which works in a similar mechanism to varenicline. It is safe, efficacious, and cost-effective for smoking cessation.

View Article and Find Full Text PDF

Background: Tumour hypoxia resulting from inadequate perfusion is common in many solid tumours, including prostate cancer, and constitutes a major limiting factor in radiation therapy that contributes to treatment resistance. Emerging research in preclinical animal models indicates that exercise has the potential to enhance the efficacy of cancer treatment by modulating tumour perfusion and reducing hypoxia; however, evidence from randomised controlled trials is currently lacking. The 'Exercise medicine as adjunct therapy during RADIation for CAncer of the prostaTE' (ERADICATE) study is designed to investigate the impact of exercise on treatment response, tumour physiology, and adverse effects of treatment in prostate cancer patients undergoing external beam radiation therapy (EBRT).

View Article and Find Full Text PDF

Deep Learning Superresolution for Simultaneous Multislice Parallel Imaging-Accelerated Knee MRI Using Arthroscopy Validation.

Radiology

January 2025

From the Department of Radiology, Division of Musculoskeletal Radiology, NYU Grossman School of Medicine, 660 1st Ave, 3rd Fl, Rm 313, New York, NY 10016 (S.S.W., J.V., R.K., E.H.P., J.F.); Department for Diagnostic and Interventional Radiology, Eberhard Karls University Tübingen, University Hospital Tübingen, Tübingen, Germany (S.S.W.); Department of Radiology, University Hospital Basel, Basel, Switzerland (J.V.); Department of Radiology, Hospital do Coraçao, São Paulo, Brazil (T.C.R.); Academic Surgical Unit, South West London Elective Orthopaedic Centre (SWLEOC), London, United Kingdom (D.D.); Department of Radiology, Balgrist University Hospital, Zurich, Switzerland (B.F.); Department of Radiology, Jeonbuk National University Hospital, Jeonju, Republic of Korea (E.H.P.); Research Institute of Clinical Medicine of Jeonbuk National University, Biomedical Research Institute of Jeonbuk National University Hospital, Jeonju, Republic of Korea (E.H.P.); Medscanlagos Radiology, Cabo Frio, Brazil (A.S.); Centre for Data Analytics, Bond University, Gold Coast, Australia (S.E.S.); Siemens Healthineers AG, Erlangen, Germany (I.B.); and Siemens Medical Solutions USA, Malvern, Pa (G.K.).

Background Deep learning (DL) methods can improve accelerated MRI but require validation against an independent reference standard to ensure robustness and accuracy. Purpose To validate the diagnostic performance of twofold-simultaneous-multislice (SMSx2) twofold-parallel-imaging (PIx2)-accelerated DL superresolution MRI in the knee against conventional SMSx2-PIx2-accelerated MRI using arthroscopy as the reference standard. Materials and Methods Adults with painful knee conditions were prospectively enrolled from December 2021 to October 2022.

View Article and Find Full Text PDF

A three-dimensional (3D) waveguide model is applied in extreme ultraviolet (EUV) lithography simulations. The 3D waveguide model is equivalent to rigorous coupled-wave analysis, but fewer field components are used to solve Maxwell's equations. The 3D waveguide model uses two components of vector potential, and , corresponding to the two polarizations.

View Article and Find Full Text PDF

Purpose: Knee osteoarthritis (KOA) is a prevalent degenerative bone and joint disease observed in clinical practice. While acupuncture has demonstrated efficacy in treating KOA, the central mechanisms underlying its effects remain ambiguous. Recently, functional magnetic resonance imaging (fMRI) has been extensively applied in studying the brain mechanisms of acupuncture analgesia.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!