The objectives of this study were to reduce the risk of showering distal vessels with thromboemboli created during percutaneous interventions of the arteries in the lower extremities. Distal protection devices have been used in coronary and carotid interventions. Hence, using similar techniques, these filters and occlusion balloons were advanced past the targeted lesions and distally into femoral and popliteal arteries. Once opened, these devices allowed standard angioplasty and stent placement and captured the dislodged thromboemboli. Five cases were performed with the distal protection devices. One case used the distal occlusion balloon and four with the filter system. All five passed the lesion and were deployed. All five devices were retrieved without incident and were retrieved with substantial debris. There were no adverse events. The use of distal protection to treat high-risk or unstable lesions in the lower extremities shows great promise. Further case will be needed to evaluate the device for feasibility and safety.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ccd.20254DOI Listing

Publication Analysis

Top Keywords

distal protection
16
protection devices
12
lower extremities
12
distal
6
devices
5
early experience
4
experience application
4
application distal
4
protection
4
devices treatment
4

Similar Publications

Lack of intracranial atherosclerosis in various atherosclerotic mouse models.

Vasc Biol

January 2025

M Daemen, Pathology, Amsterdam UMC Location AMC, Amsterdam, Netherlands.

Background: Although mice are used extensively to study atherosclerosis of different vascular beds, limited data is published on the occurrence of intracranial atherosclerosis. Since intracranial atherosclerosis is a common cause of stroke and is associated with dementia, a relevant animal model is needed to study these diseases.

Methods And Results: We examined the presence of intracranial atherosclerosis in different atherogenic mouse strains and studied differences in vessel wall characteristics in mouse and human tissue in search for possible explanations for the different atherosclerotic susceptibility between extracranial and intracranial vessels.

View Article and Find Full Text PDF

Unlabelled: Subsequent fracture rates and associated mortality were compared before and after the introduction of fracture liaison service (FLS). In 100,198 women and men, FLS was associated with 13% and 10% lower risk of subsequent fragility fractures and 18% and 15% lower mortality. The study suggests that FLS may prevent fractures.

View Article and Find Full Text PDF

Coil embolization of cerebral aneurysms often encounters challenges in achieving complete filling of the aneurysm sac due to complex shapes and hemodynamic factors, frequently resulting in the formation of a residual cavity (RC) at the aneurysm neck. The hemodynamic mechanisms underlying RC formation and growth, however, remain poorly understood. Computational fluid dynamics (CFD) analysis, combined with silent MRA free from contrast agents and metal artifacts, offers a promising approach to elucidate these mechanisms, potentially enhancing the clinical management of cerebral aneurysms post-coiling.

View Article and Find Full Text PDF

Form-function relationships often have tradeoffs: if a material is tough, it is often inflexible, and vice versa. This is particularly relevant for the elephant trunk, where the skin should be protective yet elastic. To investigate how this is achieved, we used classical histochemical staining and second harmonic generation microscopy to describe the morphology and composition of elephant trunk skin.

View Article and Find Full Text PDF

The construction of a double-layer colon-targeted delivery system based on zein-shellac complex and gelatin-isomaltooligosaccharide Maillard product: In vitro and in vivo evaluation.

Food Res Int

January 2025

College of Life Sciences, Northeast Forestry University, Harbin 150040, PR China; Key Laboratory of Forest Food Resources Utilization of Heilongjiang Province, Harbin 150040, PR China. Electronic address:

In this study, we developed a double-layer colon-targeted microcapsule. It used the Maillard product of gelatin-isomaltooligosaccharide (GI180) and zein-shellac complex (ZS) as bio-based materials, plant extracts (MPL) and Lactobacillus plantarum JJBYG12 (JJBYG12) were co-encapsulated, endowing them with strong resistance to harsh environments and precise intestinal adhesion and targeting ability. The research results indicated that ZS11 exhibits hydrogen bonding and electrostatic interactions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!