[Biphasic ceramic wedge and plate fixation with locked adjustable screws for open wedge tibial osteotomy].

Rev Chir Orthop Reparatrice Appar Mot

Service d'Orthopédie-Traumatologie, CHU La Meynard, 97200 Fort-de-France, Martinique.

Published: October 2004

Purpose Of The Study: The aim of this radiological study was to evaluate the use of a biphasic ceramic wedge combined with plate fixation with locked adjustable screws for open wedge tibial osteotomy.

Material And Methods: Twenty-six consecutive patients (27 knees) underwent surgery between December 1999 and March 2002 to establish a normal lower-limb axis. The series included 6 women and 20 men, mean age 50 years (16 right knees and 11 left knees). Partial weight-bearing with crutches was allowed on day 1. A standard radiological assessment was performed on day 1, 90, and 360 (plain AP and lateral stance films of the knee). A pangonogram was performed before surgery and at day 360. Presence of a lateral metaphyseal space, development of peripheral cortical bridges, and osteointegration of the bone substitute-bone interface were evaluated used to assess bone healing. The medial tibial angle between the line tangent to the tibial plateau and the anatomic axis of the tibia (beta) was evaluated to assess preservation of postoperative correction. The HKA angle was determined.

Results: Three patients were lost to follow-up and 23 patients (24 knees) were retained for analysis. At last follow-up, presence of peripheral cortical bridges and complete filling of the lateral metaphyseal space demonstrated bone healing in all patients. Good quality osteointegration was achieved since 21 knees did not present an interface between the bone substitute and native bone (homogeneous transition zone). The beta angle was unchanged for 23 knees. A normal axis was observed in patients (16 knees) postoperatively.

Discussion: Use of a biphasic ceramic wedge in combination with plate fixation with locked adjustable screws is a reliable option for open wedge tibial osteotomy. The bone substitute fills the gap well. Tolerance and integration are optimal. Bone healing is achieved. Plate fixation with protected weight bearing appears to be a solid assembly, maintaining these corrections.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0035-1040(04)70429-8DOI Listing

Publication Analysis

Top Keywords

plate fixation
16
ceramic wedge
12
fixation locked
12
locked adjustable
12
adjustable screws
12
open wedge
12
wedge tibial
12
patients knees
12
bone healing
12
screws open
8

Similar Publications

Introduction: Aseptic recalcitrant nonunion (ARNU) of the femur and tibia is an entity in which the absence of bony union, misalignment, and limb length discrepancies (LLD) coexist. Currently, the management of these cases lacks consensus. This study aimed to describe the bone union rate and deformity correction outcomes in patients with ARNU of the femur or tibia treated with the Induced Membrane Technique (IMT).

View Article and Find Full Text PDF

Introduction: Numerous orthopaedic procedures including dynamic hip screw plating and various osteotomies require placement of a reference guide pin or K wire to direct bone cuts or for drilling screw holes. Appropriate positioning of these wires is a critical component of surgery. Irrespective of whether one is a seasoned surgeon or an apprentice, these wires often need repositioning and readjustment.

View Article and Find Full Text PDF

Treatment of posterolateral tibial plateau fractures through the articular line approach.

BMC Musculoskelet Disord

January 2025

Department of Orthopedics, Lishui Central Hospital, Zhejiang, 323000, China.

Background: Posterolateral tibial plateau fractures pose significant challenges for orthopedic surgeons due to the anatomical risks associated with the posterolateral approach. Despite numerous surgical techniques available, there lacks a consensus on the optimal approach.

Methods: Articular line incision approach was employed on 12 patients suffering from posterolateral tibial plateau fractures.

View Article and Find Full Text PDF

Before patients begin out-of-bed exercises following internal fixation surgery for acetabular fractures, turning over in bed serves as a crucial intervention to mitigate complications associated with prolonged bed rest. However, data on the safety of this maneuver post-surgery are limited, and the biomechanical evidence remains unclear. This study aims to introduce a novel loading protocol designed to preliminarily simulate the action of turning over in bed and to compare the biomechanical properties of two fixation methods for acetabular fractures under this new protocol.

View Article and Find Full Text PDF

Background: Bicondylar tibial plateau fractures are often associated with significant soft tissue compromise making operative treatment challenging. Dual plating through a two-incision approach following temporary external fixation has been shown to improve complication rates although deep infection rates remain high.The objective was to evaluate early outcomes following a novel technique of percutaneous application of the medial plate superficial to the pes anserinus tendons.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!