Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Cardiac safety pharmacology focuses mostly on the drug-induced prolongation of the QT interval in the electrocardiogram. A prolonged QT interval is an important indicator for an increased risk of severe ventricular arrhythmia. Guidelines demand safety tests addressing QT prolongation in vitro and in vivo before a drug enters clinical trials. If safety risks will be detected not until an advanced stage of preclinical drug development, a considerable sum of money has already been invested into the drug development process. To prevent this, high-throughput systems have been developed to obtain information on the potential toxicity of a substance earlier. We will discuss in this publication that the QT-Screen system, which is based on primary cardiac myocytes, is able to provide a sufficient throughput for secondary screening. With this system, extracellular field potentials can be recorded from spontaneously beating cultures of mammalian or avian ventricular cardiac myocytes simultaneously on 96 channels. The system includes software-controlled and automated eight-channel liquid handling, data acquisition, and analysis. These features allow a user-friendly and unsupervised operation. The throughput is over 100 compounds in six replicates and with full dose-response relationships per day. This equals a maximum of approximately 6,000 data points per day at an average cost for consumables of 0.20 US pennies (U.S.) per data point. The system is intended for a non-good laboratory practice-compliant screening; however, it can be adapted to be used in a good laboratory practice environment.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1089/adt.2004.2.507 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!