A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determination of environmentally important metal ions by fluorescence quenching in anionic micellar solution. | LitMetric

Determination of environmentally important metal ions by fluorescence quenching in anionic micellar solution.

Analyst

Departamento de Quimica, Universidade Federal de Santa Catarina, CEP 88040-900, Florianopolis, SC, Brazil.

Published: February 2005

This work describes the effect of a variety of metal ions as quenchers of the fluorescence of naphthalene, in aqueous micellar solutions of sodium dodecyl sulfate (SDS). The quenching by the metal ions can be adequately described by the Stern-Volmer equation and the best signal to noise ratios are obtained with low micellized detergent concentrations. Apparent Stern-Volmer constants decrease in the order: Fe3+ > Cu2+ > Pb2+ > Cr3+ > Ni2+ and directly reflect the relative sensitivity of the method for these ions. Detection limits (defined as three times the standard deviation of the blank for n= 10) for the fluorescence quenching of naphthalene by the metal ions in aqueous micellar SDS are in the range of 1.0 x 10(-6) to 1.0 x 10(-5) mol dm(-3). The proposed fluorescence quenching method shows good repeatibility for a variety of added quencher metal ions, indicating that anionic micelle-enhanced fluorescence quenching by metal ions constitutes an analytical method of rather general application.

Download full-text PDF

Source
http://dx.doi.org/10.1039/b409600bDOI Listing

Publication Analysis

Top Keywords

metal ions
24
fluorescence quenching
16
aqueous micellar
8
quenching metal
8
ions
7
metal
6
fluorescence
5
quenching
5
determination environmentally
4
environmentally metal
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!