5-Hydroxytryptophol glucuronide (GTOL) is the major excretion form of 5-hydroxytryptophol (5-HTOL), a minor serotonin metabolite under normal conditions. Because the concentration of 5-HTOL is markedly increased following consumption of alcohol, measurement of 5-HTOL is used as a sensitive biomarker for detection of recent alcohol intake. This study describes the development and evaluation of a liquid chromatography-electrospray ionization mass spectrometry (LC-MS) procedure for direct quantification of GTOL in human urine. Deuterium labelled GTOL (GTOL-(2)H(4)) was used as internal standard. GTOL was isolated from urine by solid-phase extraction on a C(18) cartridge prior to injection onto a gradient eluted Hypurity C(18) reversed-phase HPLC column. The detection limit of the method was 2.0 nmol/L and the measuring range 6-8500 nmol/L. The intra- and inter-assay coefficients of variation were <3.5% (n=10) and <6.0% (n=9), respectively. The new LC-MS method was highly correlated with an established GC-MS method for urinary 5-HTOL (r(2)=0.99, n=70; mean 5-HTOL/GTOL ratio=1.10). This is the first direct assay for quantification of GTOL in urine. The method is suitable for routine application.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jchromb.2004.11.026 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!