Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/S0079-6123(04)48011-X | DOI Listing |
Sci Rep
January 2025
Research Unit of Health Sciences and Technology, University of Oulu, Oulu, Finland.
Optical techniques, such as functional near-infrared spectroscopy (fNIRS), contain high potential for the development of non-invasive wearable systems for evaluating cerebral vascular condition in aging, due to their portability and ability to monitor real-time changes in cerebral hemodynamics. In this study, thirty-six healthy adults were measured by single channel fNIRS to explore differences between two age groups using machine learning (ML). The subjects, measured during functional magnetic resonance imaging (fMRI) at Oulu University Hospital, were divided into young (age ≤ 32) and elderly (age ≥ 57) groups.
View Article and Find Full Text PDFEye (Lond)
January 2025
Division of Clinical Neuroscience, Department of Ophthalmology, University of Nottingham, Nottingham, UK.
Background/objectives: Anterior segment optical Coherence Tomography (AS-OCT) is used extensively in imaging the cornea in health and disease. Our objective was to analyse and monitor corneal vascularisation (CVas) through the corresponding back-shadows visible on AS-OCT.
Subjects/methods: AS-OCT scans were obtained from 26 consecutive patients (eyes) with CVas of different aetiologies.
Sci Rep
January 2025
Mallinckrodt Institute of Radiology, Washington University School of Medicine, 4515 McKinley Ave., St. Louis, MO, 63110, USA.
Functional magnetic resonance imaging (fMRI) has dramatically advanced non-invasive human brain mapping and decoding. Functional near-infrared spectroscopy (fNIRS) and high-density diffuse optical tomography (HD-DOT) non-invasively measure blood oxygen fluctuations related to brain activity, like fMRI, at the brain surface, using more-lightweight equipment that circumvents ergonomic and logistical limitations of fMRI. HD-DOT grids have smaller inter-optode spacing (~ 13 mm) than sparse fNIRS (~ 30 mm) and therefore provide higher image quality, with spatial resolution ~ 1/2 that of fMRI, when using the several source-detector distances (13-40 mm) afforded by the HD-DOT grid.
View Article and Find Full Text PDFNat Commun
January 2025
Department of Physics, Harvard University, Cambridge, MA, USA.
High-resolution fluorescence imaging of ultracold atoms and molecules is paramount to performing quantum simulation and computation in optical lattices and tweezers. Imaging durations in these experiments typically range from a millisecond to a second, significantly limiting the cycle time. In this work, we present fast, 2.
View Article and Find Full Text PDFSci Bull (Beijing)
January 2025
Key Laboratory of Ocean Observation-Imaging Testbed of Zhejiang Province, Ocean College, Zhejiang University, Hangzhou 310058, China. Electronic address:
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!