Validation of a test method for the measurement of methanol emissions from stationary sources.

J Air Waste Manag Assoc

Center for Environmental Measurements and Quality Assurance, Research Triangle Institute, Research Triangle Park, North Carolina 27709, USA.

Published: January 1995

Title III of the 1990 Clean Air Act Amendments designated methanol as a pollutant to be regulated. The U.S. Environmental Protection Agency (EPA), through a contract with Research Triangle Institute, has developed a method for measuring methanol emissions from stationary sources. The methanol sampling train (MST) consists of a glass-lined heated probe, two condensate knockout traps, and three sorbent cartridges packed with Anasorb 747. Samples are desorbed with a 1:1 mixture of carbon disulfide (CS2) and N,N-dimethylformamide (DMF). Condensate water and CS2/ DMF samples are analyzed by gas chromatography with flame ionization detection. The MST has a practical quantitation limit of approximately 3 ppm for a 20-L sample. Samples were shown to be stable for at least two weeks after collection. Field tests of the MST and the National Council of the Paper Industry for Air and Stream Improvement (NCASI) methanol sampling method were conducted at two pulp and paper mills. Sampling and analysis procedures followed EPA Method 301 requirements. The sampling location for the first field test was the inlet vent to a softwood bleach plant scrubber, where the methanol concentration was approximately 30 ppm. The mean recovery of spike was 108.3% for the MST method and 81.6% for the NCASI method. Although neither method showed significant bias at the 95% confidence level, the between-methods bias was significantly different. A second field test was conducted at a vent from a black liquor oxidation tank where the methanol concentration was approximately 350 ppm. Mean spike recoveries were 96.6 and 94.2% for the MST and NCASI methods, respectively. The biases of the two methods and the between-methods bias were not significantly different for the second field test.

Download full-text PDF

Source
http://dx.doi.org/10.1080/10473289.1995.10467338DOI Listing

Publication Analysis

Top Keywords

field test
12
methanol emissions
8
emissions stationary
8
stationary sources
8
methanol sampling
8
methanol concentration
8
between-methods bias
8
bias second
8
second field
8
method
7

Similar Publications

The development of stable and tunable polycyclic aromatic compounds (PACs) is crucial for the advancement of organic optoelectronics. Conventional PACs, such as acenes, often suffer from poor stability due to photooxidation and oligomerization, which are linked to their frontier molecular orbital energy levels. To address these limitations, we designed and synthesized a new class of π-expanded indoloindolizines by merging indole and indolizine moieties into a single polycyclic framework.

View Article and Find Full Text PDF

Numerous cities in the Russian Federation have joined the World Health Organization's (WHO) Global Network for Age-Friendly Cities and Communities since 2011. In order to do quantitative evaluations of the age-friendliness of cities, the Age-Friendly Cities and Communities Questionnaire (AFCCQ) was developed in the Netherlands. The purpose of this study was to translate and test the validity and reliability of the AFCCQ for use in the Russian Federation, and to study the views on the age-friendliness of the city of Kazan in the Republic of Tatarstan from an intergenerational perspective.

View Article and Find Full Text PDF

The sensation of sng (pronounced/səŋ/, the Romanization form of or soreness in Taiwanese Southern Min) associated with a composite of unique sensations, is a novel phenotype for acupoint stimulation. It is perceived by test participants but also by experienced practitioners as a sensation of "taking the bait" (by fish when fishing), a characteristic heavy and tight sensation from the needle. Here, we propose that sng is a powerful biomarker for associated with successful manual acupuncture.

View Article and Find Full Text PDF

Chemotherapy is a crucial cancer treatment, but its effectiveness requires precise monitoring of drug concentrations in patients. This study introduces an innovative electrochemical strip sensor design to detect and continuously monitor methotrexate (MTX), a key chemotherapeutic drug. The sensor is crafted through an eco-friendly synthesis process that produces porous reduced graphene oxide (PrGO), which is then integrated with gold nanocomposites and polypyrrole (PPy) to boost the performance of a screen-printed carbon electrode (SPCE).

View Article and Find Full Text PDF

In the pursuit of personalized medicine, there is a growing demand for computational models with parameters that are easily obtainable to accelerate the development of potential solutions. Blood tests, owing to their affordability, accessibility, and routine use in healthcare, offer valuable biomarkers for assessing hemostatic balance in thrombotic and bleeding disorders. Incorporating these biomarkers into computational models of blood coagulation is crucial for creating patient-specific models, which allow for the analysis of the influence of these biomarkers on clot formation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!