Animals are becoming more and more common as in vitro and in vivo models for the human spine. Especially the sheep cervical spine is stated to be of good comparability and usefulness in the evaluation of in vivo radiological, biomechanical and histological behaviour of new bone replacement materials, implants and cages for cervical spine interbody fusion. In preceding biomechanical in vitro examination human cervical spine specimens were tested after fusion with either a cubical stand-alone interbody fusion cage manufactured from a new porous TiO/glass composite (Ecopore) or polymethyl-methacrylate (PMMA) after discectomy. First experience with the use of the new material and its influence on the primary stability after in vitro application were gained. After fusion of 10 sheep cervical spines in the levels C2/3 and C4/5 in each case with PMMA and with an Ecopore-cage, radiologic as well as computertomographic examinations were performed postoperatively and every 4 weeks during the following 2 and 4 months, respectively. Apart from establishing our animal model, we analysed the radiological changes and the degree of bony fusion of the operated segments during the course. In addition we performed measurements of the corresponding disc space heights (DSH) and intervertebral angles (IVA) for comparison among each other, during the course and with the initial values. Immediately after placement of both implants in the disc spaces the mean DSH and IVA increased (34.8% and 53.9%, respectively). During the following months DSH decreased to a greater extent in the Ecopore-segments than in the PMMA-segments, even to a value below the initial value (p>0.05). Similarly, the IVA decreased in both groups in the postoperative time lapse, but more distinct in the Ecopore-segments (p<0.05). These changes in terms of a subsidence of the implants, were confirmed morphologically in the radiological examination in the course. The radiologically evaluated fusion, i.e. bony bridging of the operated segments, was more pronounced after implantation of an Ecopore-cage (83%), than after PMMA interposition (50%), but did not gain statistical significance. In this first in vivo examination of our new porous ceramic bone replacement material we showed its application in the spondylodesis model of the sheep cervical spine. Distinct radiological changes regarding evident subsidence and detectable fusion of the segments, operated on with the new biomaterial, were seen. We demonstrated the radiological changes of the fused segments during several months and analysed them morphologically, before the biomechanical evaluation will be presented in a subsequent publication.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1515/BMT.2004.066 | DOI Listing |
BMC Oral Health
January 2025
The First Affiliated Hospital of Chongqing Medical University, No. 1 Youyi Road, Yuzhong District, Chongqing, 400016, P.R. China.
Objective: To investigate the effects of modified twin-block appliances (MTBA) on obstructive sleep apnea (OSA) and mandibular retrognathia and the changes in the upper airway, hyoid bone position, and hypoxia-related inflammatory marker levels in children with OSA.
Methods: This study included children with OSA and mandibular retrognathia and those with class I without mandibular retrognathia (n = 35 each). The experimental group comprised children with OSA and mandibular retrognathia managed using MTBA.
No Shinkei Geka
January 2025
Department of Neurosurgery, Tsukazaki Hospital.
It is important to be aware of the indications, surgical procedure selection, and associated complications. This chapter focuses on basic screw placement techniques, emphasizing on safety with each anchor placement. Familiarity with managing surgical accidents is also important.
View Article and Find Full Text PDFNo Shinkei Geka
January 2025
Tama Neurosurgery Clinic, Kanagawa.
Posterior cervical decompression surgery is safe and effective. It was developed to safely and reliably decompress nerve tissues. Maximising the reconstruction and maintenance of the posterior neck tissue has been reported and developed.
View Article and Find Full Text PDFNo Shinkei Geka
January 2025
Spine Center, Aichi Medical University Hospital.
In Japan, cervical artificial disc replacement was approved by the Pharmaceuticals and Medical Devices Agency in December 2017, and two products, Mobi-C by Zimmer Biomet and Prestige LP by Medtronic, are on the market. Cervical artificial disc replacement preserves cervical motion; however, the device must be place carefully on the midline to take full advantage of its features. In addition, a reliable foraminotomy is required to cure or prevent radiculopathy due to residual foraminal stenosis.
View Article and Find Full Text PDFNo Shinkei Geka
January 2025
Department of Spinal Surgery, Akita Cerebrospinal and Cardiovascular Center.
Anterior cervical fixation is an excellent surgical technique for the removal of anterior compressive elements affecting the spinal cord and nerve roots while addressing cervical instability. However, it is important to recognize the unique challenges posed by the proximity of critical structures, including the trachea, esophagus, carotid sheath, and recurrent laryngeal nerve. Access to the upper cervical spine is often limited to the mandible.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!