Aim: We previously reported the laboratory methodology for producing patient-specific irradiated autologous tumor-cell products derived from short-term cultured tumor cells from resected renal cell carcinoma, and described preliminary clinical results. In this study, we report the final clinical results and efforts to define vaccine potency on the basis of clinical outcome for these 25 patients with advanced renal cell carcinoma.
Materials And Methods: Approximately 10(8) cells from successful short-term cell lines were irradiated, frozen in aliquots of 10(7) cells, then thawed and administered subcutaneously (s.c.) once a week for 3 weeks, then once a month for 5 months. Patients included 19 men and 6 women, who were 43-82 years of age. Six (6) patients had a large primary lesion, 2 patients had regionally advanced disease, 3 patients had been rendered disease-free by surgical resection of distant metastases, and 14 patients had measurable distant metastatic disease.
Results: The vaccines were well tolerated, and no delayed autoimmune effects were documented. Delayed-type hypersensitivity (DTH) tests of irradiated tumor cells were positive in only 1 of 25 patients at week 0, but converted to positive in 6 of 18 patients of DTH-negative patients who were retested at week 4. Objective response rate in patients who had measurable metastatic disease was 0 of 14 patients. With a median follow-up of greater than 7 years from the date of the first DTH test, median survival is 33.4 months, 5-year survival is 43%, and 10 patients are alive 3-12 years later. The 7 DTH+ patients survived a median of 2.5 years, and 3 patients are alive after 3, 4, and 7 years. There was no correlation between the number of irradiated cells or viable irradiated cells injected and tumor DTH reactivity or survival.
Conclusion: This approach is feasible and the therapy is well tolerated, but clinical benefit was not established in this trial. Any further exploration of this product should be limited to the adjuvant setting in a randomized trial.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1089/cbr.2004.19.570 | DOI Listing |
Adv Ther
December 2024
Global Medical and Patient Affairs, Servier, Suresnes, France.
Introduction: The aim of the observational SIMPLE study was to assess real-life effectiveness and safety of a single-pill combination (SPC) of perindopril arginine/amlodipine in a broad range of subjects with newly diagnosed mild-to-moderate hypertension treated in Canadian general practice.
Methods: Treatment-naïve participants aged 18-65 years with mild-to-moderate hypertension, whose physicians decided to initiate the perindopril/amlodipine SPC, were recruited from Canadian clinical practice from October 2017 to February 2019. Participants were followed at 3- (M3) and 6-month (M6) visits after treatment initiation.
Adv Ther
December 2024
GSK, US Value Evidence and Outcomes, Collegeville, PA, 19426-0989, USA.
Introduction: Chronic obstructive pulmonary disease (COPD) is associated with exacerbations which can reduce quality of life and increase mortality. Single-inhaler triple therapy (SITT) is recommended for maintenance treatment of COPD among patients experiencing exacerbations despite dual-therapy use. This real-world comparative effectiveness study compared the impact of SITTs, fluticasone furoate/umeclidinium/vilanterol (FF/UMEC/VI), and budesonide/glycopyrrolate/formoterol fumarate (BUD/GLY/FORM), on COPD exacerbations and mortality.
View Article and Find Full Text PDFPacing Clin Electrophysiol
December 2024
Division of Cardiology, Department of Medicine, Weill Cornell Medicine, New York Presbyterian Hospital, New York, USA.
Leadless pacing technology now includesdedicated atrial helix-fixation leadless pacemakers (LPs), expanding theapplication of leadless devices for patients with sinus node dysfunction andatrioventricular block during sinus rhythm. This first reportedcase-series of atrial LPs describes and discusses the potential use-casescenarios of recently approved helix-fixation atrial LPs. The article highlights important concepts regarding their use, including implantationtechniques, programming, battery conservation, and the low rate of progressionof AV block in patients implanted with AAI(R) pacemakers.
View Article and Find Full Text PDFPacing Clin Electrophysiol
December 2024
Electrophysiology and Cardiac Pacing Unit, Pellegrini Hospital, Naples, Italy.
Reel's syndrome (RS) is an unusual cause of pacemaker lead dislodgement. We present the case of a 59-year-old female patient with Down syndrome (DS) implanted with a dual-chamber endovascular pacemaker due to symptomatic sinus node disfunction, reporting several syncopal episodes in last days and showing abnormal electrical parameters at the 2-months follow-up due to RS. The malfunctioning device was removed and an endocardial leadless pacing system was implanted.
View Article and Find Full Text PDFCurr Rheumatol Rep
December 2024
Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Avenue, CLS-937, Boston, MA, 02215, USA.
Purpose Of Review: Kidney injury due to lupus nephritis (LN) is a severe and sometimes life-threatening sequela of systemic lupus erythematosus. Autoimmune injury to podocytes has been increasingly demonstrated to be a key driver of LN-related kidney injury because these cells play key roles in glomerular filtration barrier homeostasis. Irreparable podocyte injury impairs these processes and can lead to proteinuria, which is an indicator of poor prognosis in LN.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!