Measurement of laser-induced alignment of molecules by cross defocusing.

Opt Lett

Laboratoire de Physique de l'Université de Bourgogne, Unité Mixte de Recherche, Centre National de la Recherche Scientifique 5027, B.P. 47 870, 21 078 Dijon Cedex, France.

Published: January 2005

The field-free alignment of CO2 produced in response to the excitation of a molecule by a high-intensity femtosecond pump pulse is measured with a simple coronography-like technique. The technique is based on the defocusing of a time-delayed probe pulse produced by the spatial distribution of aligned molecules. In the intensity regime explored here, the technique is shown to give valuable information about dynamic alignment. With the help of simulations, the degree of alignment is extracted from the data.

Download full-text PDF

Source
http://dx.doi.org/10.1364/ol.30.000070DOI Listing

Publication Analysis

Top Keywords

measurement laser-induced
4
alignment
4
laser-induced alignment
4
alignment molecules
4
molecules cross
4
cross defocusing
4
defocusing field-free
4
field-free alignment
4
alignment co2
4
co2 produced
4

Similar Publications

Laser reduction of graphene oxide (GO) is a promising approach for achieving flexible, robust, and electrically conductive graphene/polymer composites. Resulting composite materials show significant technological potential for energy storage, sensing, and bioelectronics. However, in the case of insulating polymers, the properties of electrodes show severely limited performance.

View Article and Find Full Text PDF

The laser-induced damage threshold (LIDT) is a key measure of an optical component's resistance to laser damage, making its accurate determination crucial. Following the ISO 21254 standards, we studied the measurement strategy and uncertainty fitting method for laser damage, establishing a calculation model for uncertainty. Research indicates that precise LIDT measurement can be achieved by using a small energy level difference and conducting multiple measurements.

View Article and Find Full Text PDF

Hydrodynamic radius () is a descriptive metric of protein structure with the potential to impact drug development, disease diagnosis, and other important research areas of molecular biology. Common instrumental methods for molecular size characterization are disadvantageous due to high sample consumption, measurements made in non-physiological conditions, and/or inaccurate size determinations. Capillary Taylor dispersion analysis (TDA) is a molecular sizing method that utilizes nL sample volumes and achieves absolute size determination without calibration or comparison to standards.

View Article and Find Full Text PDF

Fabrication of hierarchical sapphire nanostructures using ultrafast laser induced morphology change.

Nanotechnology

January 2025

Walker Department of Mechanical Engineering, The University of Texas at Austin, 204 E. Dean Keeton St., Austin, Texas, 78712-1139, UNITED STATES.

Sapphire is an attractive material in photonic, optoelectronic, and transparent ceramic applications that stand to benefit from surface functionalization effects stemming from micro/nanostructures. Here we investigate the use of ultrafast lasers for fabricating nanostructures in sapphire by exploring the relationship between irradiation parameters, morphology change, and selective etching. In this approach an ultrafast laser pulse is focused on the sapphire substrate to change the crystalline morphology to amorphous or polycrystalline, which is characterized by examining different vibrational modes using Raman spectroscopy.

View Article and Find Full Text PDF

Nanosecond Nanothermometry in an Electron Microscope.

Nano Lett

January 2025

University Paris-Saclay, CNRS, Laboratoire de Physique des Solides, Orsay 91405, France.

Thermal transport in nanostructures plays a critical role in modern technologies. As devices shrink, techniques that can measure thermal properties at nanometer and nanosecond scales are increasingly needed to capture transient, out-of-equilibrium phenomena. We present a novel pump-probe photon-electron method within a scanning transmission electron microscope (STEM) to map temperature dynamics with unprecedented spatial and temporal resolutions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!