A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Influence of acid etching and enamel beveling on the 6-month clinical performance of a self-etch dentin adhesive. | LitMetric

This study tested the hypothesis that beveling and/or etching enamel does not affect the 6-month clinical performance of the self-etch adhesive Clearfil SE Bond in class V noncarious lesions. With Institutional Review Board approval, 34 patients were enrolled in this study. A total of 120 noncarious cervical lesions were selected and assigned to 4 groups: (1) Clearfil SE Bond was applied without any cavity preparation; (2) After the enamel was beveled, Clearfil SE Bond was applied; (3) After the enamel was etched for 15 seconds with 35% phosphoric acid, Clearfil SE Bond was applied; (4) After the enamel was beveled and etched with 35% phosphoric acid for 15 seconds, Clearfil SE Bond was applied. A microfilled composite resin was used for all restorations. Six months after initial placement, 120 restorations (a 100% recall rate) were re-evaluated. Retention rates at 6 months were 100% for all groups. Sensitivity to air improved from baseline to 6 months, but the overall difference was not statistically significant. The 6-month retention rate of the self etch dentin adhesive system Clearfil SE Bond was not improved by enamel beveling or by enamel etching. For the self-etch material Clearfil SE Bond, instrumentation or etching of enamel may not be critical for its clinical performance at 6 months.

Download full-text PDF

Source

Publication Analysis

Top Keywords

clearfil bond
28
bond applied
16
etching enamel
12
clinical performance
12
enamel
8
enamel beveling
8
6-month clinical
8
performance self-etch
8
dentin adhesive
8
enamel beveled
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!