Aim: Although the quality of currently available urinary tests for detecting antibody to Helicobacter pylori (H pylori) have been proved in some populations, the accuracy has not been studied regarding patients who suffer from pulmonary tuberculosis with multi-drug treatments. The present study was conducted to evaluate the accuracy of these urinary tests for antibody to H pylori in these patients.

Methods: Serum samples from 61 inpatients with pulmonary tuberculosis were tested using enzyme immunoassay, and urine samples were assayed by enzyme-linked immunosorbent assay method (URINELISA) and immunochromatography method (RAPIRAN). Medicines prescribed to the patients were recorded for medical charts, to evaluate the influences on the results of urinary tests.

Results: The sensitivity, specificity, and consistency of URINELISA against the serum test were 93.1%, 65.6%, and 78.6% respectively, and those of RAPIRAN were 86.2%, 93.7%, and 90.1% respectively, which were almost equal to the data previously reported. Prescribed medicines had little influence on the results.

Conclusion: The two urinary tests for detecting H pylori antibody have a diagnostic accuracy in patients with pulmonary tuberculosis given multiple anti-tuberculosis drugs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4205350PMC
http://dx.doi.org/10.3748/wjg.v11.i3.412DOI Listing

Publication Analysis

Top Keywords

urinary tests
16
pulmonary tuberculosis
16
tests antibody
8
antibody helicobacter
8
helicobacter pylori
8
patients pulmonary
8
tests detecting
8
pylori
5
reliability urinary
4
tests
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!