Measurement of air trapping, intrinsic positive end-expiratory pressure, and dynamic hyperinflation in mechanically ventilated patients.

Respir Care

Critical Care Center, Hospital de Sadabell, Institut Universitari Fundaciò Parc Taulì, Corporaciò Parc Taulì, Universitad Autònoma de Barcelona, Sadabell, Spain.

Published: January 2005

Severe airflow obstruction is a common cause of acute respiratory failure. Dynamic hyperinflation affects tidal ventilation, increases airways resistance, and causes intrinsic positive end-expiratory pressure (auto-PEEP). Most patients with asthma and chronic obstructive pulmonary disease have dynamic hyperinflation and auto-PEEP during mechanical ventilation, which can cause hemodynamic compromise and barotrauma. Auto-PEEP can be identified in passively breathing patients by observation of real-time ventilator flow and pressure graphics. In spontaneously breathing patients, auto-PEEP is measured by simultaneous recordings of esophageal and flow waveforms. The ventilatory pattern should be directed toward minimizing dynamic hyperinflation and auto-PEEP by using small tidal volume and preserving expiratory time. With a spontaneously breathing patient, to reduce the work of breathing and improve patient-ventilator interaction, it is crucial to set an adequate inspiratory flow, inspiratory time, trigger sensitivity, and ventilator-applied PEEP. Ventilator graphics are invaluable for monitoring and treatment decisions at the bedside.

Download full-text PDF

Source

Publication Analysis

Top Keywords

dynamic hyperinflation
16
intrinsic positive
8
positive end-expiratory
8
end-expiratory pressure
8
hyperinflation auto-peep
8
breathing patients
8
spontaneously breathing
8
auto-peep
5
measurement air
4
air trapping
4

Similar Publications

Adult patients with central airway tumors commonly present with dyspnea on exertion. These patients may remain asymptomatic until more than half of the airway diameter is obliterated. Anesthesia for debulking a central airway tumor is challenging.

View Article and Find Full Text PDF

MRI-assessed Dynamic Hyperinflation Induced by Tachypnea in Chronic Obstructive Pulmonary Disease: The SPIROMICS-HF Study.

Radiol Cardiothorac Imaging

February 2025

From the Department of Biomedical Engineering (X.Z.) and Columbia Magnetic Resonance Research Center (CMRRC) (W.S.), Columbia University, New York, NY; Departments of Medicine (C.B.C., J.P.F.) and Radiology (J.P.F.), University of California at Los Angeles, Los Angeles, Calif; Department of Radiology, Weill Cornell Medicine, New York, NY (M.R.P.); Department of Radiology (M.R.P., S.M.D., S.J.), Department of Medicine (M.C.B., R.G.B.), Department of Epidemiology (R.G.B.), Division of Pediatric Gastroenterology, Hepatology and Nutrition, Department of Pediatrics (W.S.), and Institute of Human Nutrition (W.S.), Columbia University Irving Medical Center, 632 W 168th St, PH-17, New York, NY 10032; Department of Radiology (B.A.V., J.A.C.L.) and Division of Pulmonary and Critical Care Medicine, Department of Medicine, School of Medicine (N.N.H.), Johns Hopkins University, Baltimore, Md; Department of Radiology, University of Michigan, Ann Arbor, Mich (P.P.A.); Department of Radiology, University of Wisconsin-Madison School of Medicine and Public Health, Madison, Wis (D.A.B.); Gillings School of Global Public Health, University of North Carolina, Chapel Hill, NC (D.C.); Departments of Radiology, Medicine, and the Roy J. Carver Department of Biomedical Engineering, University of Iowa, Iowa City, Iowa (E.A.H.); Sections on Cardiology and Geriatrics, Department of Internal Medicine, Wake Forest University School of Medicine, Winston-Salem, NC (D.W.K.); Division of Pulmonary, Critical Care, Sleep, and Allergy (J.A.K.) and Department of Radiology, College of Medicine (M.G.M.), University of Illinois at Chicago, Chicago, Ill; Department of Radiology and Biomedical Imaging (Y.J.L., J.L.), Division of Pulmonary, Critical Care, Sleep, and Allergy, Department of Medicine, School of Medicine (P.G.W.), and Cardiovascular Research Institute (P.G.W.), University of California at San Francisco, San Francisco, Calif; Division of Pulmonary and Critical Care Medicine, Department of Medicine, Wake Forest University, Winston-Salem, NC (J.O., S.P.P.); Division of Pulmonary Medicine, Department of Medicine, Mayo Clinic, Phoenix, Ariz (V.E.O.); Department of Medicine, University of Utah, Salt Lake City, Utah (R.P.); Department of Radiology, Mayo Clinic, Rochester, Minn (J.D.S.); Department of Radiology, Hannover Medical School, Hannover, Germany (J.V.C.); and BREATH, Member of the German Center for Lung Research (DZL), Hannover, Germany (J.V.C.).

Purpose To assess the repeatability of real-time cine pulmonary MRI measures of metronome-paced tachypnea (MPT)-induced dynamic hyperinflation and its relationship with chronic obstructive pulmonary disease (COPD) severity. Materials and Methods SubPopulations and InteRmediate Outcome Measures In COPD Study (SPIROMICS) (ClinicalTrials.gov identifier no.

View Article and Find Full Text PDF

Introduction: COPD is characterised by airflow obstruction, expiratory airway collapse and closure causing expiratory flow limitation (EFL) and hyperinflation. Supine posture may worsen ventilatory function in COPD, which may cause hyperinflation to persist and contribute to symptoms of orthopnoea and sleep disturbance. Our aim was to determine the impact of supine posture on hyperinflation, dynamic elastance and EFL in COPD and healthy subjects.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!