Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The COBAS TaqMan HCV Test (TaqMan HCV; Roche Molecular Systems Inc., Branchburg, N.J.) for hepatitis C virus (HCV) performed on the COBAS TaqMan 48 Analyzer (Roche Molecular Systems) currently relies on a manual sample processing method. Implementation of an automated sample processing method would facilitate the clinical use of this test. In this study, we evaluated the performance characteristics of TaqMan HCV following automated sample processing by the MagNA Pure LC instrument (MP; Roche Applied Science, Indianapolis, Ind.). The analytical sensitivity of TaqMan HCV following sample processing by MP was 8.1 IU/ml (95% confidence interval, 6.1 to 15.2). The assay showed good linearity (R(2) = 0.99) across a wide range of HCV RNA levels (25 to 5 x 10(6) IU/ml), with coefficients of variation ranging from 10% to 46%. Among 83 clinical specimens, the sensitivity and specificity of TaqMan HCV were 100% and 95%, respectively, when compared to the COBAS AMPLICOR hepatitis C virus test, version 2.0 (COBAS AMPLICOR; Roche Molecular Systems), with TaqMan HCV detecting two more HCV RNA-positive specimens than COBAS AMPLICOR. Both specimens were confirmed to be HCV RNA positive by the VERSANT HCV RNA qualitative test (Bayer HealthCare LLC, Tarrytown, N.Y.). There was also strong correlation (R(2) = 0.95) and good agreement between the results from TaqMan HCV and the VERSANT HCV RNA 3.0 assay (bDNA) (Bayer HealthCare LLC) among a group of 93 clinical specimens. The MP is a versatile, labor-saving sample processing platform suitable for reliable performance of TaqMan HCV.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC540141 | PMC |
http://dx.doi.org/10.1128/JCM.43.1.293-298.2005 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!