Rational design of a chromo- and fluorogenic hybrid chemosensor material for the detection of long-chain carboxylates.

J Am Chem Soc

Centro de Investigación en Química Molecular Aplicada, Departamento de Química, Universidad Politécnica de Valencia, Camino de Vera s/n, E-46071 Valencia, Spain.

Published: January 2005

A strategy for the rational design of a new optical sensor material for the selective recognition of long-chain carboxylates in water is presented. The approach relies on the combination of structure-property relationships to single out the optimal molecular sensor unit and the tuning of the sensing characteristics of an inorganic support material. A spacer-substituted 7-urea-phenoxazin-3-one was employed as the signaling moiety and a mesoporous trimethylsilylated UVM-7 (MCM-41 type) material served as the solid support. The sensor material shows the advantageous features of both modules that is absorption and emission in the visible spectral range, a fluorescence red-shift and enhancement upon analyte coordination, and the amplification of noncovalent (binding) and hydrogen-bonding (recognition) interactions in the detection event. Besides these basic results that are related to the design and performance of the sensor material, the paper discusses general aspects of amido-substituted phenoxazinone photophysics and addresses some general features of molecular anion recognition chemistry in aqueous vs nonaqueous media, utilizing steady-state and time-resolved optical as well as NMR spectroscopies. Detailed studies on potentially competing biochemical species and a first access to the schematic model of the response of the sensor material as obtained by a combination of fluorescence lifetime distribution analysis and Langmuir-type fitting of the gross binding constants complement the key issues of the paper.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ja045683nDOI Listing

Publication Analysis

Top Keywords

sensor material
16
rational design
8
long-chain carboxylates
8
material
7
sensor
5
design chromo-
4
chromo- fluorogenic
4
fluorogenic hybrid
4
hybrid chemosensor
4
chemosensor material
4

Similar Publications

Purpose: The aim of this study was to propose a lateral oscillating device for the prevention of pressure ulcers by understanding the mechanisms of tissue protection in healthy individuals during prolonged decubitus. We also sought to determine the optimal time interval for oscillation, considering peak pressure peaks and tolerable pressure limits as a function of individual characteristics such as age, weight, height, gender, and BMI.

Methods: A quasi-experimental, descriptive and analytical observational study was conducted between January 2022 and June 2023 with a sample of 25 healthy volunteers.

View Article and Find Full Text PDF

Background: Food safety has attracted increasing attention in recent years. Harmful gases often produced during food storage have devastating effects on human health and ecosystems, and identifying and detecting them is essential. To date, many traditional methods have been used to monitor the freshness of food products.

View Article and Find Full Text PDF

Advances in the design and application of contactless conductivity detectors for separation, flow-through, microfluidic and sensing techniques: A review.

Anal Chim Acta

February 2025

Department of Hygiene, Third Faculty of Medicine, Charles University, Ruská 87, 100 00, Prague 10, Czech Republic. Electronic address:

The review focuses on the design of detection cells, the use of microcontrollers for processing and evaluation of the detection signal, and the development of multi-detection systems for electromigration, liquid chromatography, flow-through and microfluidic techniques. A separate section is the introduction of modern 3D printing techniques and the use of new printing materials for the design of multidetection systems. In addition to traditional utilisation in separation techniques, new versions of contactless conductivity detectors are finding applications in FIA, SIA, portable and paper based analytical systems or as independent sensors.

View Article and Find Full Text PDF

Background: The buildup of methylparaben (MP), a broad-spectrum antimicrobial preservative with endocrine-disrupting properties, in environmental sources, especially aquatic systems, has become a significant concern due to its adverse health effects, including allergic reactions, promoting the risk of developing cancer, and inducing reproductive disorders. Hence, introducing inexpensive and easy-to-use monitoring devices for rapid, selective, and sensitive detection and quantification of MP is highly desirable. In this context, electrochemical platforms have proven to be attractive options due to their remarkable features, such as ease of fabrication and use, short response time, and acceptable sensitivity, accuracy, and selectivity.

View Article and Find Full Text PDF

In situ decoration of AuPd nanoparticles on MOF derived ZnO for ultra-high response and low detection limit trimethylamine detection.

Anal Chim Acta

February 2025

School of Physics and Electronic Information Engineering, Henan Polytechnic University, Jiaozuo, 454003, China. Electronic address:

Background: Trimethylamine (TMA) is a colorless, volatile gas with a strong irritating odor. Prolonged exposure to a certain amount of TMA can cause symptoms such as dizziness, nausea and difficulty breathing, and may even be life-threatening. Therefore, effective detection of TMA is crucial.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!