Objective: To investigate the relationship between drainage angle configuration with untreated intraocular pressure (IOP) and optic disc cupping in subjects with chronic angle-closure glaucoma (CACG).

Design: Prospective, observational study.

Participants: Two hundred seventy-five Asian subjects with CACG who participated in a randomized controlled trial that investigated the IOP-reducing effect of latanoprost and timolol.

Methods: Chronic angle-closure glaucoma was defined as the presence of glaucomatous optic neuropathy (with or without a visual field defect), an anterior chamber angle in which the pigmented trabecular meshwork was not visible for at least 180 degrees on gonioscopy, and evidence of peripheral anterior synechiae (PAS) in association with elevated IOP of 21 mmHg or more. Static and dynamic gonioscopy were performed, the angles were graded in each quadrant according to the Shaffer scheme, and the number of clock hours of PAS was recorded. The untreated IOP and vertical cup-to-disc ratio were correlated with mean angle width and extent of PAS.

Main Outcome Measures: Mean angle width, clock hours of PAS, IOP, and vertical cup-to-disc ratio.

Results: Most subjects were female (75%), and the mean age was 62.9+/-9.4 years. The mean angle width was 0.77+/-0.53 and the mean number of clock hours of PAS was 4.77+/-3.2 hours. Untreated IOP correlated with angle width (r = -0.23; P<0.001) and clock hours of PAS (r = 0.22; P<0.001). Vertical cup-to-disc ratio also correlated with angle width (r = -0.17; P = 0.004) and PAS (r = 0.28; P<0.001). Performing a multiple linear regression using baseline IOP as the outcome variable with age, gender, clock hours of PAS, and angle width as predictors, there was a 0.39-mmHg (95% confidence interval, 0.15-0.63) increase in baseline untreated IOP for each unit increase in clock hours of PAS (P = 0.002).

Conclusions: In subjects with CACG, the extent of PAS and a narrower width of the drainage angle were associated with higher untreated IOP and a larger vertical cup-to-disc ratio.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ophtha.2004.06.033DOI Listing

Publication Analysis

Top Keywords

angle width
16
chronic angle-closure
12
angle-closure glaucoma
12
clock hours
12
hours pas
12
drainage angle
8
intraocular pressure
8
optic disc
8
disc cupping
8
cupping subjects
8

Similar Publications

What Is the Optimal Geometry of Dissolving Microneedle Arrays? A Literature Review.

Pharmaceutics

January 2025

Department of Pharmaceutical Technology and Biopharmacy, University of Groningen, 9713 AV Groningen, The Netherlands.

The application of dissolving microneedle arrays (DMNAs) is an emerging trend in drug and vaccine delivery as an alternative for hypodermic needles or other less convenient drug administration methods. The major benefits include, amongst others, that no trained healthcare personnel is required and that the recipient experiences hardly any pain during administration. However, for a successful drug or vaccine delivery from the DMNA, the microneedles should be inserted intact into the skin.

View Article and Find Full Text PDF

Effects of Thickness of the Corn Seed Coat on the Strength of Processed Biological Materials.

Materials (Basel)

January 2025

Department of Dairy and Process Engineering, Food Sciences and Nutrition, Poznan University of Life Sciences, Wojska Polskiego 31, 60-624 Poznan, Poland.

The strength and energy of processed biological materials depend, among others, on their properties. Despite the numerous studies available, the relationship between the internal structure of corn grains and their mechanical properties has not yet been explained. Hence, the aim of the work is to explore the relationship between the internal composition of maize kernels and its mechanical properties by studying the impact of the maize seed coat thickness on its breakage susceptibility.

View Article and Find Full Text PDF

Metasurface-Coated Liquid Microlens for Super Resolution Imaging.

Micromachines (Basel)

December 2024

State Key Laboratory for Manufacturing System Engineering, Xi'an Jiaotong University, Xi'an 710054, China.

Inspired by metasurfaces' control over light fields, this study created a liquid microlens coated with a layer of Au@TiO, Core-Shell nanospheres. Utilizing the surface plasmon resonance (SPR) effect of Au@TiO, Core-Shell nanospheres, and the formation of photonic nanojets (PNJs), this study aimed to extend the imaging system's cutoff frequency, improve microlens focusing, enhance the capture capability of evanescent waves, and utilize nanospheres to improve the conversion of evanescent waves into propagating waves, thus boosting the liquid microlens's super-resolution capabilities. The finite difference time domain (FDTD) method analyzed the impact of parameters including nanosphere size, microlens sample contact width, and droplet's initial contact angle on super-resolution imaging.

View Article and Find Full Text PDF

Analysis of Acoustic Surface Wave Focused Unidirectional Interdigital Transducers Using Coupling-of-Mode Theory.

Micromachines (Basel)

December 2024

School of Physics and Electronic Information, Yunnan Normal University, No. 1 Yuhua Area, Chenggong District, Kunming 650500, China.

In cell or droplet separation, high acoustic wave energy of a surface acoustic wave (SAW) device is required to generate sufficient acoustic radiation force. In this paper, the electrode width-control floating electrode focused unidirectional interdigital transducer (EWC-FEFUDT) is proposed due to its enhanced focusing properties. The performance of the EWC-FEFUDT is investigated using the Coupling-of-Mode (COM) theory, and the COM parameter is extracted using the Finite Element Method (FEM).

View Article and Find Full Text PDF

Objective: To compare the influence of different emergence profile of implants in mandibular molar on the peri-implant soft tissue.

Methods: Forty-four implants were divided into two equal groups by mucosal thickness, ≥2 mm (group A) or < 2 mm (group B), and were randomly included in the test group and the control group. In the control group, the patients were treated by a prosthesis with no transmucosal modifications (subgroups A1 and B1).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!