A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Biodegradable self-expanding poly-L/D-lactic acid vascular stent: a pilot study in canine and porcine iliac arteries. | LitMetric

Purpose: To report results of an in vivo pilot study to evaluate the biocompatibility and delivery system of a new biodegradable vascular stent and validate the study design.

Methods: Two self-expanding intravascular stents, a biodegradable poly-D/L-lactic acid (PLA) and a medical stainless steel stent (Wallstent) were implanted in the common iliac arteries of 2 postpuberal female pigs and 3 laboratory-bred beagle dogs. Specimens were harvested after 45 days in the dogs and 32 days in the pigs for histomorphometry of the stented iliac artery segments. Preliminary measurements were made to assess the reliability of the quantitative histomorphometric measurements before final measurements.

Results: Histomorphometry analyses showed that mean luminal diameter and area were decreased in the PLA stent group (1.97+/-0.48 mm and 14+/-6.4 mm2, respectively) compared to the control stent group (4.28+/-0.83 mm and 61+/-19 mm2, respectively). The intimal thickness was higher in the PLA stent group (0.65+/-0.07 mm) than in the control group (0.44+/-0.21 mm). The mean injury score was 0.19+/-0.12 in the PLA stent group and 0.78+/-0.39 in the controls. In the PLA stent group, the mean inflammation score was 1.46+/-0.78 compared to 0.58+/-0.40 in the control group. There were no differences observed between the animal models.

Conclusions: The PLA stent showed increased neointimal formation and reduced patency during early follow-up. Mechanical properties of the new biodegradable vascular stents are still inadequate, and the stent and the delivery device require modifications. The study methods were assessed as reliable and reproducible.

Download full-text PDF

Source
http://dx.doi.org/10.1583/04-127MR.1DOI Listing

Publication Analysis

Top Keywords

pla stent
20
stent group
20
stent
10
vascular stent
8
pilot study
8
iliac arteries
8
biodegradable vascular
8
control group
8
group
7
pla
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!