Contrast-enhanced peripheral MR angiography using SENSE in multiple stations: feasibility study.

J Magn Reson Imaging

Department of Radiology, Cardiovascular Research Institute Maastricht, Maastricht University Hospital, Maastricht, The Netherlands.

Published: January 2005

Purpose: To investigate if the use of parallel imaging is feasible and beneficial for peripheral contrast-enhanced magnetic resonance angiography (CE-MRA).

Materials And Methods: A total of 19 consecutive patients underwent peripheral CE-MRA using SENSE with two-fold reduction in the upper and lower leg stations. Conventional nonaccelerated imaging using constant level appearance (CLEAR) was used in the aortoiliac station. The findings were compared with those in a similar patient group that underwent peripheral CE-MR angiography using our standard imaging protocol without SENSE. Intraarterial digital subtraction angiography (IA-DSA) was used as the standard of reference. Lower extremity vessels were divided into anatomic segments (aortoiliac, upper legs, lower legs) for review. In each anatomic segment signal- and contrast-to-noise ratios (SNR, CNR), venous contamination, subjective image quality, as well as sensitivity and specificity, were determined for both patient groups.

Results: SNR and CNR improved significantly for the aortoiliac and upper leg segments (all P-values < or = 0.001). Small reductions were seen in the frequency of disturbing venous enhancement (P = not significant). There were no significant differences with regards to subjective image quality or diagnostic accuracy (all P > 0.3). Overall sensitivity and specificity in the SENSE group were 81% and 95%, respectively. For the non-SENSE group, these values were 79% and 96%, respectively.

Conclusion: Preliminary results show that three-station peripheral CE-MRA using a full length peripheral arterial coil in combination with SENSE in the upper and lower leg stations is feasible and useful for further optimization of peripheral MRA. Using SENSE allows for routine, high-quality depiction of the entire peripheral vascular tree including the pedal arch. Higher SENSE factors are needed for further optimization.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jmri.20240DOI Listing

Publication Analysis

Top Keywords

underwent peripheral
8
peripheral ce-mra
8
upper lower
8
lower leg
8
leg stations
8
aortoiliac upper
8
snr cnr
8
subjective image
8
image quality
8
sensitivity specificity
8

Similar Publications

Importance: Perioperative bleeding is common in general surgery. The POISE-3 (Perioperative Ischemic Evaluation-3) trial demonstrated efficacy of prophylactic tranexamic acid (TXA) compared with placebo in preventing major bleeding without increasing vascular outcomes in noncardiac surgery.

Objective: To determine the safety and efficacy of prophylactic TXA, specifically in general surgery.

View Article and Find Full Text PDF

Background And Objective: Neuronal intranuclear inclusion disease (NIID) is a multifaceted disorder impacting both the central and peripheral nervous systems. This study aims to investigate the clinical and electrophysiological characteristics of peripheral neuropathy in patients with NIID.

Methods: In this cross-sectional study, patients diagnosed with NIID were prospectively recruited from multiple centers across China between October 2017 and May 2024.

View Article and Find Full Text PDF

The study aimed to verify the physiological and metabolic parameters associated with the time to task failure (TTF) during cycling exercise performed within the severe-intensity domain. Forty-five healthy and physically active males participated in two independent experiments. In experiment 1, after a graded exercise test, participants underwent constant work rate cycling efforts (CWR) at 115% of peak power output to assess neuromuscular function (Potentiated twitch) pre- and post-exercise.

View Article and Find Full Text PDF

Objective: Superior vena cava syndrome (SVC) is a debilitating disease, and surgical reconstruction has been described with some of the best results using spiral great saphenous vein (SGSV) grafts. SGSV grafts can be difficult to construct, and a long segment of saphenous vein is needed. Femoral vein has been an excellent conduit for infected aortic and peripheral reconstructions in our hands, and we sought to review outcomes using this conduit for SVC reconstruction.

View Article and Find Full Text PDF

Background: Recent literature indicates that COVID-19 infection is a negative predictor of good outcomes following elective orthopedic surgery. However, the ideal timing of surgery after infection is unclear. The purpose of this study was to compare the rates of post-operative complications between those who underwent elective orthopedic surgery <50 days and >50 days after COVID-19 infection.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!