The use of iodinated or gadolinium-based contrast media in pregnant or lactating women often causes concerns in the radiology department because of the principle of not exposing a fetus or neonate to any drugs. Because of the uncertainty about the use of contrast media during pregnancy and lactation, the Contrast Media Safety Committee of the European Society of Urogenital Radiology decided to review the literature and draw up guidelines. An extensive literature search was carried out and summarized in a report. Based on the limited information available, simple guidelines have been drawn up. The report and guidelines were discussed at the 11th European Symposium on Urogenital Radiology in Santiago de Compostela, Spain. Mutagenic and teratogenic effects have not been described after administration of gadolinium or iodinated contrast media. Free iodide in radiographic contrast medium given to the mother has the potential to depress fetal/neonatal thyroid function. Neonatal thyroid function should be checked during the 1st week if iodinated contrast media have been given during pregnancy. No effect on the fetus has been seen after gadolinium contrast media. Only tiny amounts of iodinated or gadolinium-based contrast medium given to a lactating mother reach the milk, and only a minute proportion entering the baby's gut is absorbed. The very small potential risk associated with absorption of contrast medium may be considered insufficient to warrant stopping breast-feeding for 24 h following either iodinated or gadolinium contrast agents.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00330-004-2583-yDOI Listing

Publication Analysis

Top Keywords

contrast media
28
gadolinium contrast
12
media pregnancy
12
contrast medium
12
contrast
11
iodinated gadolinium
8
pregnancy lactation
8
iodinated gadolinium-based
8
gadolinium-based contrast
8
urogenital radiology
8

Similar Publications

Background: Multidose iodinated contrast media (ICM) injectors have shown promise in reducing ICM waste. This study aims to evaluate the impact of patient volume on ICM waste reduction in multidose injectors.

Methods: CT studies performed over one-year period with a multidose injector at our emergency CT unit.

View Article and Find Full Text PDF

A systematic review of the comparative effects of sound and music interventions for intensive care unit patients' outcomes.

Aust Crit Care

December 2024

Department of Music, Canadian Centre for Ethnomusicology (CCE), Department of Performing Arts, Faculty of Communication and Media Studies, University for Development Studies, Ghana; Department of Music, Faculty of Arts, University of Alberta, 3-98 Fine Arts Building, Edmonton, AB, T6G 2C9, Canada. Electronic address:

Background: Despite syntheses of evidence showing efficacy of music intervention for improving psychological and physiological outcomes in critically ill patients, interventions that include nonmusic sounds have not been addressed in reviews of evidence. It is unclear if nonmusic sounds in the intensive care unit (ICU) can confer benefits similar to those of music.

Objective: The aim of this study was to summarise and contrast available evidence on the effect of music and nonmusic sound interventions for the physiological and psychological outcomes of ICU patients based on the results of randomised controlled trials.

View Article and Find Full Text PDF

Purpose: This study aimed to evaluate the use of chatbot and video education to reduce anxiety in patients with breast cancer undergoing RT.

Methods And Materials: This randomized controlled trial included patients with breast cancer scheduled for RT after surgery at an outpatient department of radiation oncology in a cancer center, randomly assigned to four groups: (1) Video+Chatbot, (2) Video+Paper, (3) Paper+Chatbot, and (4) Paper+Paper. In each group, patients received information regarding the treatment process and were frequently asked questions using the designated tool.

View Article and Find Full Text PDF

To realize the aim of easy and accurate detection of ammonia and picric acid (PA) in both aqueous and vapor phases based on function-oriented investigation principles, in the present study, we include a luminescent performance with recognition performance, taking into account the application conditions. Zn(II) ions with luminescence qualities and an amine-substituted imidazole moiety with selective recognition properties towards picric acid and ammonia are coupled to generate a novel 1D luminous Zn(II) coordination polymer, Zn-CP [{Zn(II)( 2-ABZ)2(2-BDC)}].MeOH]∞, where 2-ABZ and 2-BDC stand for terephthalic acid and protonated 2 aminobenzimidazole, respectively.

View Article and Find Full Text PDF

Objective: This study explored the value of stomach ultrasound reporting and data system (Su-RADS) and two-dimensional shear wave elastography (2D-SWE) in the diagnosis of benign and malignant lesions of the gastric wall, evaluating the feasibility of combining the two methods for the diagnosis of gastric wall lesions.

Methods: 113 patients with gastric wall lesions were examined after oral gastric ultrasound contrast agent, and the grades of the gastric wall lesions were classified according to Su-RADS. Moreover, 2D-SWE was performed to measure the E value of the lesions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!