Y chromosome-specific short tandem repeat (Y-STR) analysis has become another widely accepted tool for human identification. The PowerPlex Y System is a fluorescent multiplex that includes the 12 loci: DYS19, DYS385a/b, DYS389I/II, DYS390, DYS391, DYS392, DYS393, DYS437, DYS438 and DYS439. This panel of markers incorporates the 9-locus European minimal haplotype (EMH) loci recommended by the International Y-STR User Group and the 11-locus set recommended by the Scientific Working Group on DNA Analysis Methods (SWGDAM). Described here are inter-laboratory results from 17 developmental validation studies of the PowerPlex Y System and include the following results: (a) samples distributed between laboratories and commercial standards produced expected and reproducible haplotypes; (b) use of common amplification and detection instruments were successfully demonstrated; (c) full profiles were obtained with standard 30 and 32 cycle amplification protocols and cycle number (24-28 cycles) could be modified to match different substrates (such as direct amplification of FTA paper); (d) complete profiles were observed with reaction volumes from 6.25 to 50 microL; (e) minimal impact was observed with variation of enzyme concentration; (f) full haplotypes were observed with 0.5-2x primer concentrations; however, relative yield between loci varied with concentration; (g) reduction of magnesium to 1mM (1.5 mM standard) resulted in minimal amplification, while only partial loss of yield was observed with 1.25 mM magnesium; (h) decreasing the annealing temperature by 2-4 degrees C did not generate artifacts or locus dropout and most laboratories observed full amplification with the annealing temperature increased by 2 degrees C and significant locus dropout with a 4 degrees C increase in annealing temperature; (i) amplification of individual loci with primers used in the multiplex produced the same alleles as observed with the multiplex amplification; (j) all laboratories observed full amplification with >or = 125 pg of male template with partial and/or complete profiles observed using 30-62.5 pg of DNA; (k) analysis of < or = 500 ng of female DNA did not yield amplification products; (l) the minor male component of a male/female mixture was observed with < or =1200-fold excess female DNA with the majority of alleles still observed with 10,000-fold excess female; (m) male/male mixtures produced full profiles from the minor contributor with 10-20-fold excess of the major contributor; (n) average stutter for each locus; (o) precision of sizing were determined; (p) human-specificity studies displayed amplification products only with some primate samples; and (q) reanalysis of 102 non-probative casework samples from 65 cases produced results consistent with original findings and in some instances additional identification of a minor male contributor to a male/female mixture was obtained. In general, the PowerPlex Y System was shown to have the sensitivity, specificity and reliability required for forensic DNA analysis.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.forsciint.2004.07.008 | DOI Listing |
Forensic Sci Int Genet
January 2025
Forensic DNA Division, National Forensic Service, Wonju, South Korea. Electronic address:
Y-chromosomal short tandem repeats (Y-STRs) at rapidly mutating (RM) loci have been suggested as tools for differentiating paternally related males. RMplex is a recently developed system that incorporates 26 RM loci and four fast-mutating (FM) loci, targeting 44 male-specific loci. Here, we evaluated the RMplex by estimating Y-STR mutation rates and the overall differentiation rates for 542 Korean father-son pairs, as well as the genetic population values for 409 unrelated males.
View Article and Find Full Text PDFForensic Sci Int Genet
January 2025
Division of Biological Traces, Netherlands Forensic Institute, Laan van Ypenburg 6, The Hague 2497 GB, the Netherlands; University of Amsterdam, Swammerdam Institute for Life Sciences, Amsterdam, the Netherlands.
Massively Parallel Sequencing (MPS) has gained interest in the forensic community over the past decade. Most of the published MPS methods focus on specialty applications intended for use in a limited number of samples with protocols that are relatively laborious. Recent developments using Reverse-Complement PCR enable an efficient MPS protocol suited for routine analysis of high numbers of samples.
View Article and Find Full Text PDFInt J Legal Med
November 2024
Institute of Forensic Medicine, Faculty of Medicine, University of Ljubljana, Korytkova 2, Ljubljana, 1000, Slovenia.
Identification of human remains is a challenge in forensic genetics without relatives or personal items available. In Slovenia, a Konfin II mass grave from the Second World War (WWII) was found, containing skeletal remains of 65 victims. The archival documents detailing victims' information describe 45 persons of which 33 could be considered Germanic and 12 Slavic.
View Article and Find Full Text PDFInt J Legal Med
November 2024
Department of Forensic Science, School of Basic Medical Sciences, Central South University, No. 172. Tongzipo Road, Changsha, 410013, China.
The PowerPlex 35GY System (Promega, USA) is an advanced eight-dye multiplex STR kit, incorporating twenty-three autosomal STR loci, eleven Y chromosome STR loci, one sex determining marker Amelogenin, and two quality indicators. This multiplex system includes 20 CODIS loci and up to 15 mini-STR loci with sizing values less than 250 bases. In this study, validation for PowerPlex 35GY System was conducted following the guidelines of SWGDAM, encompassing sensitivity, precision, accuracy, concordance, species specificity, stutter, mixture, stability, and degraded DNA.
View Article and Find Full Text PDFForensic Sci Int Genet
November 2024
Forensic Biology Laboratory, PathWest Laboratory Medicine WA, Locked Bag 2009, Nedlands, Western Australia 6009, Australia.
Forensic Biology is contingent upon matching DNA profiles between a crime sample and a reference sample. There are several capillary electrophoresis kits available to generate a short tandem repeat (STR) profile from DNA samples, while newer methods using massively parallel sequencing are slowly being implemented in forensic laboratories worldwide. During evaluation of a newer capillary electrophoresis kit, Applied Biosystems™ VeriFiler™ Plus, a discordance was observed in the Penta D locus.