A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Analysis of forces developed during mechanical preparation of extracted teeth using RaCe rotary instruments and ProFiles. | LitMetric

Analysis of forces developed during mechanical preparation of extracted teeth using RaCe rotary instruments and ProFiles.

Int Endod J

Pulp Biology and Endodontics, Department of Restorative Sciences, Graduate School, Tokyo Medical and Dental University, Tokyo 113-8548, Japan.

Published: January 2005

Aim: To compare the torque and load during instrumentation with ProFile and RaCe nickel-titanium rotary instruments.

Methodology: Thirty human incisor roots 12 mm in length were embedded in epoxy resin, and divided into three groups of 10 specimens each. Instruments employed in each group were as follows: RaCe .02 Step Back Files in group 1; RaCe .04 Step Back Files in group 2; and .04 ProFiles in group 3. Two load cells, whose outputs were connected to a digital oscilloscope, recorded torque and vertical load. Data were analysed by one-way anova.

Results: Torque values were statistically different between groups 1 and 3, and between groups 2 and 3 (torque was higher in group 3 than in groups 1 and 2). Vertical loads were statistically higher in group 3 than in groups 1 and 2.

Conclusions: Torsional and vertical forces can be evaluated during instrumentation of straight root canals using the device and methods described in this study. When the step-back technique was employed, torque and vertical load obtained with RaCe instruments were lower than that obtained with ProFiles.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1365-2591.2004.00890.xDOI Listing

Publication Analysis

Top Keywords

group race
8
race step
8
step files
8
files group
8
torque vertical
8
vertical load
8
higher group
8
group groups
8
group
6
race
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!