Aims: To establish normative current perception threshold (CPT) values with neuroselective sine-wave current in the lower urinary tract and to compare these values with square-wave current CPTs.

Materials And Methods: 10 female and 8 male healthy volunteers were used for this study. A filling cystometry was performed and CPTs were determined with square-wave current at a frequency of 2.5 Hz and with neuroselective sine-wave current at 5 (C-fiber), 250 (Adelta-fiber), and 2000 Hz (Abeta-fiber) in the bladder, the posterior, and the distal urethra.

Results: Bladder CPTs were significantly higher compared with CPTs in the posterior urethra (P < 0.028) and in the distal urethra (P < 0.002) with all three sine-wave frequencies. No significant difference was found with any sine-wave frequency between the posterior and distal urethra (P > 0.30). Using square-wave pulses at 2.5 Hz, CPTs decreased towards the distal urethra, with a significant difference between the three stimulation sites (P < 0.0001). At all sites tested, the CPT's determined with sine-wave current at 2000 Hz were significantly higher than those at 250 Hz (P < 0.002) and 5 Hz (P < 0.001). No significant difference was found between 5 Hz and 250 Hz at any site in the LUT (P > 0.50). At all sites, CPTs determined with square-wave pulses at 2.5 Hz were significantly higher than those determined with sine-wave current at all frequencies (P < 0.001). CPTs determined with all sine-wave currents were not correlated with CPTs using square-wave pulses. There was no correlation between the volumes at which sensation of filling occurred and the CPTs.

Conclusions: We described normative values in young healthy volunteers at three sites in the LUT using sine-wave current. Although this type of current is said to be neuroselctive, this needs to be confirmed. Stimulation with sine-wave current is different and might be more physiologic compared to square-wave stimulation. Our data show that sine-wave current stimulation at 5 Hz, 250 Hz, and 2000 Hz can probably not be used as a semi-objective measurement of the sensation of bladder filling because no correlation was found between CPTs and the cystometeric sensation of filling.

Download full-text PDF

Source
http://dx.doi.org/10.1002/nau.20095DOI Listing

Publication Analysis

Top Keywords

sine-wave current
28
current
12
healthy volunteers
12
cpts determined
12
distal urethra
12
square-wave pulses
12
determined sine-wave
12
sine-wave
10
current perception
8
lower urinary
8

Similar Publications

The actuator is a critical component of the micromanipulator. By utilizing the properties of expansion and contraction, the piezoelectric actuator enables the manipulator to handle and grasp miniature objects during micromanipulation. However, in piezoelectric ceramic disc actuators with conventional surface electrode configurations, the actuating force generated in the radial direction is relatively limited.

View Article and Find Full Text PDF

Fourier-transformed alternating current voltammetry (FTacV) is a technique utilizing a combination of a periodic (frequently sinusoidal) oscillation superimposed onto a staircase or linear potential ramp. The advanced utilization of a large amplitude sine wave induces substantial nonlinear current responses. Subsequent filter processing (via Fourier-transformation, band selection, followed by inverse Fourier-transformation) generates a series of harmonics in which rapid electron transfer processes may be separated from non-Faradaic and competing electron transfer processes with slower kinetics.

View Article and Find Full Text PDF

Photonic crystals (PCs) consisting of a periodic arrangement of holes in dielectric media have found success in light manipulation and sensing. Among them, three-dimensional (3D) PCs are in high demand due to their unique properties originating from multiple photonic band gaps (PBGs) and even full ones. Here, 3D PCs based on porous anodic aluminum oxide (AAO) were fabricated for the first time.

View Article and Find Full Text PDF

Operational amplifiers (op-amps) are widely used in circuit systems. The increasing complexity of the power supply network has led to the susceptibility of the power supply port to electromagnetic interference (EMI) in circuit systems. Therefore, it is necessary to investigate the electromagnetic susceptibility (EMS) of op-amps at the power supply port.

View Article and Find Full Text PDF

Influence of Taper surface topographies on contact deformation and stresses.

J Mech Behav Biomed Mater

December 2023

School of Engineering and Materials Science, Queen Mary University of London, UK. Electronic address:

The role of bore and trunnion surface topography on the failure rate of total hip joint replacements due to trunnionosis is not clear despite significant variations in the design of taper components between manufacturers. Taper surface topography, along with other taper design parameters such as clearance, diameter, and assembly force, determine the initial interlock of the contacting surfaces after assembly; this has been related to relative motions that can cause fretting and corrosion at the taper interface. However, in most in-silico parametrical taper studies associated with taper micromotions, the bore and trunnion surfaces have been simplified using a flat surface and/or sinusoidal functions to mimic the surface roughness.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!