New scheme for positron accumulation in ultrahigh vacuum.

Phys Rev Lett

Institute of Physics, University of Tokyo, 3-8-1 Komaba, Meguro, Tokyo 153-8902, Japan.

Published: November 2004

A new positron accumulation scheme compatible with ultrahigh vacuum conditions has been developed, which is realized by preparing a high density electron plasma as high as approximately 10(11) cm(-3) and an ion cloud as energy absorbers. The present accumulation rate normalized by the intensity of 22Na positron source is (3.6+/-0.3)x10(2)e(+)/s/mCi, which is more than one and a half orders of magnitude higher than other ultrahigh vacuum compatible schemes so far reported.

Download full-text PDF

Source
http://dx.doi.org/10.1103/PhysRevLett.93.195001DOI Listing

Publication Analysis

Top Keywords

ultrahigh vacuum
12
positron accumulation
8
scheme positron
4
accumulation ultrahigh
4
vacuum positron
4
accumulation scheme
4
scheme compatible
4
compatible ultrahigh
4
vacuum conditions
4
conditions developed
4

Similar Publications

Atomic Force Microscopy of Viruses.

Subcell Biochem

December 2024

Department of Physics of the Condensed Matter, C03 and IFIMAC (Instituto de Física de la Materia Condensada). Universidad Autónoma de Madrid, Madrid, Spain.

Atomic force microscopy (AFM) makes it possible to obtain images at nanometric resolution, and to accomplish the manipulation and physical characterization of specimens, including the determination of their mechanical and electrostatic properties. AFM has an ample range of applications, from materials science to biology. The specimen, supported on a solid surface, can be imaged and manipulated while working in air, ultra-high vacuum or, most importantly for virus studies, in liquid.

View Article and Find Full Text PDF

Electroisomerization blinking of an azobenzene derivative molecule.

Nanotechnology

January 2025

University Lille, CNRS, University Polytechnique Hauts-de-France, UMR 8520-IEMN-Institut d'Electronique de Microélectronique et de Nanotechnologie, F-59000 Lille, France.

We report here the reversibility and bistability of the switching behavior in an azobenzene derivative induced by the bias applied by a scanning-tunneling microscopy (STM) tip, at low temperature and in ultra-high vacuum environment. Thisto-andto-switching were observed during STM imaging in either polarity at +2 V or -2 V, on a sub-second time scale. This results in a blinking effect visible on STM images, corresponding to the reversible switching of the azobenzene molecule under the applied STM bias through an electric field induced process.

View Article and Find Full Text PDF

Low-temperature scanning tunneling spectroscopy is a key method to probe electronic and magnetic properties down to the atomic scale, but suffers from extreme vibrational sensitivity. This makes it challenging to employ closed-cycle cooling with its required pulse-type vibrational excitations, albeit this is mandatory to avoid helium losses for counteracting the continuously raising helium prices. Here, we describe a compact ultra-high vacuum scanning tunneling microscope (STM) system with an integrated primary pulse tube cooler (PTC) for closed-cycle operation.

View Article and Find Full Text PDF

This study evaluates the air permeability of epoxy-coated normal concrete and ultra-high performance concrete (UHPC) for use in Hyperloop tube structures, where maintaining ultra-low air permeability is crucial to preserving the vacuum environment. While UHPC is recognized for its exceptionally low permeability due to its dense microstructure, this research explores epoxy-coated conventional concrete as a cost-effective alternative. Using a vacuum-based permeability test simulating Hyperloop's near-vacuum conditions, the study found that epoxy-coated concrete significantly reduced air permeability compared to uncoated concrete, with specimens coated on both sides approaching near-zero permeability.

View Article and Find Full Text PDF

A versatile setup for hydrogen isotope permeation studies.

Rev Sci Instrum

December 2024

Max-Planck-Insitut für Plasmaphysik, Boltzmannstrasse 2, Garching D-85748, Germany.

The Testbed for Analysis of Permeation of Atoms in Samples (TAPAS) is an experimental setup for ion-driven permeation studies with a focus on investigating wall materials for nuclear fusion devices. A monoenergetic, mass-filtered high-intensity keV ion beam is focused and directed onto the permeation sample by electrostatic ion optics and decelerated to the desired ion energy by a dedicated set of apertures close to the sample. We were able to obtain ion energies as low as 170 eV/D with a D3+ ion beam with an ion flux density of the order of 1020 D/m2s on a beam-wetted area of ∼33 mm2.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!