A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Design and experimental study of computer-assisted orthopaedic system for distal locking of intramedullary nails]. | LitMetric

Objective: To test the safety and accuracy of the computer-assisted orthopaedic system for distal locking of intramedullary nails and apply it to internal fixation with intramedullary nails in the lower limb.

Methods: According to the theory of mechanical arms stereotactic localization in computer-assisted orthopaedic surgery (CAOS), we design a CAOS system for distal locking of intramedullary nails. The system comprised 2 independent modules: computer-assisted imaging and registration workstation; mechanical stereotactic framework. Ten plastic tibia models, 20 plastic femur models (Synbone AG, Malans, Switzerland) and 6 human cadaver lower limbs were randomly divided into 2 groups undergoing internal fixation with intramedullary nails (Orthofix, Germany). The first group (CAOS group with 5 plastic tibia models, 10 plastic femur models, 6 human cadaver tibia, 6 human cadaver femur; each nail had 2 holes, and 2 distal locking screws were inserted in each bone, which gave a total number of 54 holes) used a computer-assisted orthopaedic system, the second group (CONTROL GROUP is the same as CAOS group) used Orthofix mechanical targeting device for distal locking. Comparison between 2 groups was made in radiation exposure time, operating time, percentage of correctly placed screws.

Results: CAOS group: operating time was (4.44 +/- 2.99) min; radiation exposure time was (1.16 +/- 0.38) min; correctly placed screws rate was (100 +/- 0)%.

Control Group: operating time was (10.42 +/- 4.18) min; radiation exposure time was (4.71 +/- 3.86) min; correctly placed screws rate was (94.44 +/- 0.36)%. Operating time and radiation exposure time in CAOS group were significantly shorter than those in control group (P < 0.05), no differences were found between 2 groups in relation to the percentage of correctly placed screws.

Conclusions: By using CAOS system for distal locking of intramedullary nails, the locking holes can be drilled accurately and safely. Radiation exposure significantly reduced.

Download full-text PDF

Source

Publication Analysis

Top Keywords

distal locking
24
intramedullary nails
20
radiation exposure
20
computer-assisted orthopaedic
16
system distal
16
locking intramedullary
16
caos group
16
exposure time
16
operating time
16
orthopaedic system
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!