Background And Purpose: Recently, 3 clinical trials revealed encouraging results in recanalization and clinical outcome in acute stroke patients when 2-MHz transcranial Doppler monitoring was applied. This study investigated whether a 1.8-MHz commercial diagnostic ultrasound device has the potential to facilitate thrombolysis using an in vitro stroke model.

Methods: Duplex-Doppler, continuous wave-Doppler, and pulsed wave (PW)-Doppler were compared on their impact on recombinant tissue plasminogen activator (rtPA)-mediated thrombolysis. Blood clots were transtemporally sonicated in a human stroke model. Furthermore, ultrasound attenuation of 5 temporal bones of different thickness was determined.

Results: In comparison, only PW-Doppler accelerated rtPA-mediated thrombolysis significantly. Without temporal bone, PW-Doppler plus rtPA showed a significant enhancement in relative clot weight loss of 23.7% when compared with clots treated with rtPA only (33.9+/-5.5% versus 27.4+/-5.2%; P<0.0005). Ultrasound attenuation measurements revealed decreases of the output intensity of 86.8% (8.8 dB) up to 99.2% (21.2 dB), depending on temporal bone thickness (1.91 to 5.01 mm).

Conclusions: Without temporal bone, PW-Doppler significantly enhanced thrombolysis. However, because of a high attenuation of ultrasound by temporal bone, no thrombolytic effect was observed in our in vitro model, although Doppler imaging through the same temporal bone was still possible.

Download full-text PDF

Source
http://dx.doi.org/10.1161/01.STR.0000150503.10480.a7DOI Listing

Publication Analysis

Top Keywords

commercial diagnostic
8
diagnostic ultrasound
8
ultrasound device
8
rtpa-mediated thrombolysis
8
device accelerate
4
accelerate thrombolysis?
4
thrombolysis? vitro
4
vitro skull
4
skull model
4
model background
4

Similar Publications

HIV self-sampling and -testing (HIVSS/ST) reduces testing barriers and potentially reaches populations who may not test otherwise. In the Netherlands, at-home HIV tests became commercially available around 2016, but data on user experiences are limited. This study aimed to explore characteristics of users and their experiences with HIVSS/ST.

View Article and Find Full Text PDF

Purpose: To evaluate the radiological and clinical outcomes in two patient groups: first, varus aligned medial meniscus posterior root tear (MMPRT) patients who underwent posteromedial open wedge high tibial osteotomy (PMOWHTO) and simultaneous root repair; second, patients with varus medial knee osteoarthritis without MMPRT who underwent PMOWHTO.

Methods: Patients had MMPRT repair concomitant with PMOWHTO and varus medial knee osteoarthritis without concomitant root tear patients who underwent PMOWHTO and were reviewed. Radiographic parameters, medial meniscus extrusion (MME) and Knee Society Scores [KSSs, including the following subscores: knee score (KS) and knee function score (KFS)] were evaluated.

View Article and Find Full Text PDF

Background: Protein abundance levels, sensitive to both physiological changes and external interventions, are useful for assessing the Alzheimer's disease (AD) risk and treatment efficacy. However, identifying proteomic prognostic markers for AD is challenging by their high dimensionality and inherent correlations.

Methods: Our study analyzed 1128 plasma proteins, measured by the SOMAscan platform, from 858 participants 55 years and older (mean age 63 years, 52.

View Article and Find Full Text PDF

Background: Neurodevelopmental conditions often exhibit overlapping symptoms, posing challenges for differential diagnosis. Developmental Coordination Disorder (DCD) manifests as fundamental motor impairments, often along with co-occurring visuospatial difficulties. Nonverbal Learning Disorder (NLD) features visuospatial core challenges, with a less consistent characterization of its motor profile.

View Article and Find Full Text PDF

Purpose: To explore the effect of different reconstruction algorithms (ASIR-V and DLIR) on image quality and emphysema quantification in chronic obstructive pulmonary disease (COPD) patients under ultra-low-dose scanning conditions.

Materials And Methods: This prospective study with patient consent included 62 COPD patients. Patients were examined by pulmonary function test (PFT), standard-dose CT (SDCT) and ultra-low-dose CT (ULDCT).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!