A sensitive and selective amperometric glucose biosensor based on platinum microparticles dispersed in nano-fibrous polyaniline (PANI) was investigated. Poly (m-phenylenediamine) (PMPD), which was employed as an anti-interferent barrier and a protective layer to platinum microparticles, was deposited onto platinum-modified PANI in the presence of glucose oxidase. The morphology of PANI, Pt/PANI and PMPD-GOD/Pt/PANI were investigated by scanning electron microscopy. The results show that PANI has a nano-fibrous morphology. The enzyme electrode exhibits excellent response performance to glucose with linear range from 2 x 10(-6) to 12 x 10(-3) M and fast response time within 7s. Due to the selective permeability of PMPD, the enzyme electrode also shows good anti-interference to uric acid and ascorbic acid. The Michaelis-Menten constant km and the maximum current density imax of the enzyme electrode were 9.34 x 10(-3) M and 917.43 microA cm(-2), respectively. Furthermore, this glucose biosensor also has good stability and reproducibility.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.bios.2004.04.024 | DOI Listing |
Nanoscale
January 2025
Department of Chemistry, College of Chemistry and Life Science, Beijing University of Technology, Beijing, 100124, China.
Metal nanoclusters (NCs), comprising tens to hundreds of metal atoms, are condensed matter with concrete molecular structures and discrete energy levels. Compared to metal atoms and nanoparticles, metal NCs exhibit unique physicochemical properties, especially fascinating electrocatalytic activities. This review focuses on recent progress in the precise synthesis of metal NCs and their applications in electrochemical analysis of various disease biomarkers.
View Article and Find Full Text PDFAnal Chem
January 2025
School of Chemistry and Chemical Engineering, South China University of Technology, Guangzhou 510632, China.
Luminol is a well-known electrochemiluminescence (ECL) fluorophore that is applied in various sensing fields as an ECL reporter. Regulating the signal off/on transition of an ECL fluorophore offers great opportunities for sensors' design; however, such attempts on luminol are extremely scarce as it was regarded to lack promising modification sites. In this study, we developed four luminol derivatives with modification at the amine site and the enol site and systematically explored possible caging strategies to regulate ECL emission.
View Article and Find Full Text PDFBiochim Biophys Acta Rev Cancer
December 2024
Fujian Clinical Research Center for Gynecological Oncology, Fujian Maternity and Child Health Hospital, College of Clinical Medicine for Obstetrics & Gynecology and Pediatrics, Fujian Medical University, Fuzhou 350001, Fujian, China; Fujian Key Laboratory of Women and Children's Critical Diseases Research, Fujian Maternity and Child Health Hospital, Fuzhou 350001, Fujian, China; Department of Gynecology, Fujian Maternity and Child Health Hospital, College of Clinical Medicine for Obstetrics & Gynecology and Pediatrics, Fujian Medical University, Fuzhou 350001, Fujian, China; School of Group Medicine and Public Health, Peking Union Medical College, Beijing 100091, China. Electronic address:
The war between humanity and malignant tumors has been ongoing, with continuous advancements in classic chemotherapy and radiotherapy regimens, targeted drugs, endocrine therapy, and immunotherapy. However, tumor cells can develop primary or secondary resistance to these treatment options, making the issue of tumor resistance a major factor affecting patient prognosis and leading to recurrence. Estrogen-related receptors (ERRs) are members of the nuclear receptor superfamily, primarily involved in regulating glucose, lipid, and amino acid metabolism, serving as a central hub for intracellular energy metabolism.
View Article and Find Full Text PDFBiomed Tech (Berl)
December 2024
Nanotechnology and Advanced Materials Research Center, University of Technology-Iraq, Baghdad, Iraq.
Objectives: Nonenzymatic biosensor-based-conductive polymers like polyaniline are highly electrochemically stable, cheap, and easy to synthesize biosensors, which is the main objective of research as well as testing applied in different pH conditions to get optimum sensitivity.
Methods: A nonenzymatic glucose biosensor based on polyaniline was electrochemically deposited on a glassy carbon electrode; the cyclic voltammetry under range applied voltage -0.2 to 1.
Biosens Bioelectron
March 2025
Programa de Pós-Graduação em Engenharia Elétrica, Universidade Federal de Minas Gerais, Belo Horizonte, MG, 31270-901, Brazil; Departamento de Engenharia Eletrônica, Universidade Federal de Minas Gerais, Belo Horizonte, MG, 31270-901, Brazil. Electronic address:
Frequent glucose monitoring is essential for effective diabetes management. Currently, glucose monitoring is done using invasive methods such as finger-pricking and subcutaneous sensing. However, these methods can cause discomfort, heighten the risk of infection, and some sensing devices need frequent calibration.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!