Intrathecal infusion is often performed using drug combinations. This study was conducted to evaluate the stability of the admixture of morphine sulfate, bupivacaine hydrochloride, and clonidine hydrochloride when used in an implantable pump under simulated clinical use conditions. SynchroMed implantable pumps were filled with an admixture and incubated at 37 degrees C for a period of 90 days. Drug admixture stored in glass vials at 4 degrees C and at 37 degrees C served as controls. Samples which included pump reservoir and catheter delivered aliquots were collected every 30 days and analyzed for drug concentrations using a stability-indicating HPLC method. All drugs contained in the admixture were stable and the original concentrations remained greater than 96%. Over 90 days, and with the pump at the simulated body temperature of 37 degrees C, there were no evident heat catalyzed or device catalyzed reactions.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jpainsymman.2004.04.011DOI Listing

Publication Analysis

Top Keywords

stability admixture
8
admixture morphine
8
morphine sulfate
8
sulfate bupivacaine
8
bupivacaine hydrochloride
8
hydrochloride clonidine
8
clonidine hydrochloride
8
hydrochloride implantable
8
pump simulated
8
hydrochloride
4

Similar Publications

The administered infusion solution is a sterile preparation that can be used directly for intravenous infusion in patients by mixing one or more intravenous drugs using aseptic operation technology. The pharmacy intravenous admixture service (PIVAS) center is a professional technical service department in hospitals, where the majority of inpatient-administered infusion solutions are prepared. During the processes of dissolution, dilution, preparation, storage, and use of intravenous drugs, the quality control of the administered infusion solution can be affected by various factors.

View Article and Find Full Text PDF

Tree species through aboveground biomass and roots are a key factors influencing the quality and quantity of soil organic matter. Our study aimed to determine the stability of soil organic matter in Luvisols under the influence of five different tree species. The study areas were located 25 km north of Krakow, in southern Poland.

View Article and Find Full Text PDF

Protective Properties of Silane Composite Coatings Modified with Poly(3,4-ethylenedioxythiophene) with Heteropolyacid on X20Cr13 and 41Cr4 Steel.

Materials (Basel)

December 2024

Department of Materials Engineering, Faculty of Production Engineering and Materials Technology, Czestochowa University of Technology, Aleja Armii Krajowej 19, 42-200 Czestochowa, Poland.

This paper describes the methodology of the preparation and analyses of the structure and anticorrosion properties of silane coatings modified with poly(3,4-ethylenedioxythiophene) (PEDOT) with phosphododecamolybdic acid (PMo). Protective coatings, consisting of vinyltrimethoxysilane (VTMS), PEDOT powder with PMo admixture (at different concentrations), and ethanol, were deposited on X20Cr13 and 41Cr4 steels by immersion. The physicochemical properties of these silane coatings (e.

View Article and Find Full Text PDF
Article Synopsis
  • Researchers prepared recycled rubber straw concrete using rubber particles and straw powder, then evaluated its frost resistance through quick-freezing tests.
  • They measured properties like elasticity, mass loss, and flexural strength during freezing and thawing, and used scanning electron microscopy (SEM) to study the concrete's microstructure post-testing.
  • A prediction model for the concrete's performance based on mixing ratios was created using optimized BP neural networks, showing high accuracy for predicting flexural strength and freeze-thaw cycle resistance.
View Article and Find Full Text PDF

Superabsorbent polymers (SAPs) are a promising admixture that can provide internal curing to freshly cast concrete and enhance concrete properties. Although many reviews have explored aspects of SAPs, the links among SAPs' chemical and physical properties, internal curing behaviors, concrete performance, and their large-scale applications are often weakly elucidated. This paper provides an additional review of the chemical structures and physical dimensions of SAPs and their effects on the internal curing kinetic behavior as well as on concrete properties, such as workability, strength, and durability.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!