A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Prospective evaluation of BDProbeTec strand displacement amplification (SDA) system for diagnosis of tuberculosis in non-respiratory and respiratory samples. | LitMetric

Prospective evaluation of BDProbeTec strand displacement amplification (SDA) system for diagnosis of tuberculosis in non-respiratory and respiratory samples.

J Med Microbiol

Centre for Medical Microbiology, Department of Infection, Royal Free & University College Medical School, Pond Street, London NW3 2PF, UK 2Department of Thoracic Medicine, Royal Free Hospital NHS Trust, Pond Street, London NW3 2PF, UK.

Published: December 2004

Nucleic acid amplification techniques (NAATs) have been demonstrated to make significant improvements in the diagnosis of tuberculosis (TB), particularly in the time to diagnosis and the diagnosis of smear-negative TB. The BD ProbeTec strand displacement amplification (SDA) system for the diagnosis of pulmonary and non-pulmonary tuberculosis was evaluated. A total of 689 samples were analysed from patients with clinically suspected TB. Compared with culture, the sensitivity and specificity for pulmonary samples were 98 and 89 %, and against final clinical diagnosis 93 and 92 %, respectively. This assay has undergone limited evaluation for non-respiratory samples and so 331 non-respiratory samples were tested, identifying those specimens that were likely to yield a useful result. These were CSF (n = 104), fine needle aspirates (n = 64) and pus (n = 41). Pleural fluid (n = 47) was identified as a poor specimen. A concern in using the SDA assay was that low-positive samples were difficult to interpret; 7.8 % of specimens fell into this category. Indeed, 64 % of the discrepant results, when compared to final clinical diagnosis, could be assigned as low-positive samples. Specimen type did not predict likelihood of a sample being in the low-positive zone. Although the manufacturers do not describe the concept of a low-positive zone, we have found that it aids clinical diagnosis.

Download full-text PDF

Source
http://dx.doi.org/10.1099/jmm.0.45780-0DOI Listing

Publication Analysis

Top Keywords

clinical diagnosis
12
strand displacement
8
displacement amplification
8
amplification sda
8
sda system
8
diagnosis
8
system diagnosis
8
diagnosis tuberculosis
8
final clinical
8
non-respiratory samples
8