Unlabelled: (99m)Tc-[bis (dimethoxypropylphosphinoethyl)-ethoxyethylamine (PNP5)]-[bis (N-ethoxyethyl)-dithiocarbamato (DBODC)] nitride (N-PNP5-DBODC or N-DBODC5) is a new monocationic myocardial perfusion tracer. We sought to compare the myocardial uptake and clearance kinetics and organ biodistribution of (99m)Tc-N-DBODC5 with (99m)Tc-sestamibi and (99m)Tc-tetrofosmin.
Methods: Seventy-five anesthetized Sprague-Dawley rats were injected intravenously with 22.2-29.6 MBq (99m)Tc-N-DBODC5 (n = 25), (99m)Tc-sestamibi (n = 25), or (99m)Tc-tetrofosmin (n = 25). Rats were euthanized at either 2, 10, 20, 30, or 60 min after injection and gamma-well counting was performed on excised organ (heart, lung, and liver) and blood samples. In 3 additional rats, serial in vivo whole-body gamma-camera imaging with each tracer was performed.
Results: (99m)Tc-N-DBODC5 cleared rapidly from the blood pool. At 2 min after injection, (99m)Tc-N-DBODC5 blood activity was significantly lower than either (99m)Tc-sestamibi or (99m)Tc-tetrofosmin (P < 0.01) and remained lower over 60 min. Myocardial (99m)Tc-N-DBODC5 uptake was rapid (2.9% +/- 0.1% injected dose/g at 2 min), and there was no significant clearance over 60 min, similar to (99m)Tc-sestamibi and (99m)Tc-tetrofosmin. All 3 tracers exhibited rapid lung clearance. Importantly, (99m)Tc-N-DBODC5 cleared more rapidly from the liver than either (99m)Tc-sestamibi or (99m)Tc-tetrofosmin. As early as 30 min after injection, (99m)Tc-N-DBODC5 heart-to-liver ratio was 5.7 +/- 1.0 versus 1.6 +/- 0.1 and 2.9 +/- 0.3 for (99m)Tc-sestamibi and (99m)Tc-tetrofosmin (P < 0.05). By 60 min, (99m)Tc-N-DBODC5 heart-to-liver ratio further increased to 18.4 +/- 2.0 compared with 2.6 +/- 0.2 and 5.8 +/- 0.7 for (99m)Tc-sestamibi and (99m)Tc-tetrofosmin (P < 0.001). The rapid blood pool, lung, and liver clearance of (99m)Tc-N-DBODC5 resulted in excellent-quality myocardial images within 30 min after injection.
Conclusion: (99m)Tc-N-DBODC5 is a promising new myocardial perfusion tracer with superior biodistribution properties. The rapid (99m)Tc-N-DBODC5 liver clearance may shorten the duration of imaging protocols by allowing earlier image acquisition and may markedly reduce the problem of photon scatter from the liver into the inferoapical wall on myocardial images.
Download full-text PDF |
Source |
---|
J Nucl Med Technol
September 2024
Nuclear Medicine Section, Department of Radiology, King Abdul-Aziz University Hospital, Jeddah, Saudi Arabia.
Myocardial perfusion imaging (MPI) provides physiologic and functional information about the heart muscle and its blood flow. Extracardiac radioactivity can interfere with visualization of the inferior wall of the myocardium, leading to poor-quality images, difficulties in interpretation, and delays in routine practice. This study aimed to identify the efficiency of having the patient consume a carbonated lemon drink to minimize the extracardiac radioactivity of Tc-sestamibi in comparison to Tc-tetrofosmin during MPI.
View Article and Find Full Text PDFTomography
January 2023
Nuclear Medicine Department, King Fahad Medical City, Riyadh 11525, Saudi Arabia.
Objective: This study aims to establish a local diagnostic reference level (LDRL) for single-photon emission tomography/computed tomography (SPECT/CT) and positron emission tomography/CT (PET/CT) with respect to myocardial perfusion imaging (MPI).
Materials And Methods: The acquisition protocol and dosimetry data on the MPI procedures of five SPECT/CT scans and one PET/CT scan were collected. Data on technitum-99m sestamibi (Tc-sestamibi), Tc-tetrofosmin, thallium-201 (Tl), and rubidium-82 (RB) were all collected from one centre via questionnaire booklets.
Ann Nucl Cardiol
August 2022
Department of Radiology, Kanazawa Medical University Hospital, Uchinada, Kahoku, Japan.
: Gated myocardial perfusion single-photon emission computed tomography (SPECT) has been used to non-invasively evaluate the left ventricular (LV) volume and function. This study aimed to measure the normal and range values for heart risk view-function (HRV-F) software using the Japanese Society of Nuclear Medicine Working Group (JSNM-WG) normal database and clarify the characteristics of the normal database. :We used 206 myocardial perfusion short-axis images from the normal database.
View Article and Find Full Text PDFComput Biol Med
February 2022
Kanazawa University Hospital, Kanazawa, Japan.
Aim: The purpose of this study was to automatically extract myocardial regions from transaxial single-photon emission computed tomography (SPECT) images using deep learning to reduce the effects of extracardiac activity, which has been problematic in cardiac nuclear imaging.
Method: Myocardial region extraction was performed using two deep neural network architectures, U-Net and U-Net ++, and 694 myocardial SPECT images manually labeled with myocardial regions were used as the training data. In addition, a multi-slice input method was introduced during the learning session while taking the relationships to adjacent slices into account.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!