Regular checks on the performance of radiotherapy treatment units are essential and a variety of protocols has been published. These protocols identify that the determination of isocentre must be accurate and unambiguous since both the localization of a radiation field on a patient and positioning aids are referenced to it. An EPID (BIS 710) with a combined light and radiation scintillation detector screen was used to assess mechanical and radiation isocentres for different collimator and gantry angles. Crosshair positions within light field images were determined from fitted Gaussian intensity profiles and then used to calculate the displacement of the mechanical isocentre. For comparison, the position of the crosshair was also recorded on a graph paper. The radiation field centre was first calculated from the set up geometry for given gantry/collimator angles and then compared with measured values to assess the displacement of the radiation isocentre. The radiation isocentre was also checked by locating a marker, positioned on the couch, on the EPID radiation images for different treatment couch angles. The mechanical and radiation isocentres were determined from the EPID light field and radiation images respectively with an accuracy of 0.3 mm using simple PC based programs. The study has demonstrated the feasibility of using the EPID to assess mechanical and radiation isocentres of a linear accelerator in a quick and efficient way with a higher degree of accuracy achieved as compared to more conventional methods, e.g. the star shot.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/BF03178670 | DOI Listing |
Nat Commun
January 2025
Center for High Pressure Science and Technology Advanced Research, Beijing, 100093, China.
Photon emission may be continuously produced from mechanical work through self-recoverable mechanoluminescence (ML). Significant progress has been made in high-performance ML materials in the past decades, but the rate-dependent ML kinetics remains poorly understood. Here, we have conducted systematic studies on the self-recoverable ML of Mn-doped SrZnOS (SrZnOS: Mn) under rapid compression up to ~10 GPa.
View Article and Find Full Text PDFInt J Biol Macromol
January 2025
College of Mechanical Engineering, Tianjin University of Commerce, Tianjin 300134, PR China. Electronic address:
To this day, energy conservation, emission reduction, and environmental protection continue to be goals pursued by humanity. Passive radiation cooling, as a zero-consumption refrigeration technology, offers substantial opportunities for reducing global energy consumption and carbon dioxide emissions. It is of great significance to develop high-performance passive radiation cooling materials from sustainable materials.
View Article and Find Full Text PDFTransl Vis Sci Technol
December 2024
Department of Biomedical Engineering, University of Houston, Houston, TX, USA.
Purpose: To assess the safety of acoustic radiation force optical coherence elastography in the crystalline lens in situ.
Methods: Acoustic radiation force (ARF) produced by an immersion single-element ultrasound transducer (nominal frequency = 3.5 MHz) was characterized using a needle hydrophone and used for optical coherence elastography (OCE) of the crystalline lens.
FASEB J
January 2025
Department of Urology, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, China.
Acute Kidney Injury (AKI) is a significant medical condition characterized by the abrupt decline in kidney function.Low-intensity pulsed ultrasound (LIPUS), a non-invasive therapeutic technique employing low-intensity acoustic wave pulses, has shown promise in promoting tissue repair and regeneration. A novel LIPUS system was developed and evaluated in rat AKI models, focusing on its effects on glomerular filtration rate (GFR), blood urea nitrogen (BUN), serum creatinine (SCr), and the Notch1-Akt-eNOS signaling pathway.
View Article and Find Full Text PDFJ Chem Phys
January 2025
Institute of Theoretical and Applied Mechanics of the Czech Academy of Sciences, Centre Telč, 58856 Telč, Czech Republic.
The time-evolution of dynamics as well as microstructure and mechanical response of phosphate-based geopolymers was probed using x-ray photon correlation spectroscopy and rheological tests. The analyzed relaxation processes in the freshly prepared geopolymer mixes evidenced a q-independent mode of the autocorrelation function, ascribed to density fluctuations of the already established molecular network, undergoing reconfiguration without significant mass transport. Upon curing, the detected motions are localized and depict a system evolving toward structural arrest dominated by slower hyperdiffusive dynamics, characterized by a compressed exponential regime, pointing to a structural relaxation process subjected to internal stresses, in a context of marked dynamical and structural heterogeneity.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!