A method is described for determining the efficient atomic number of inclusion-tissue substance, visualized in image, by the characteristic angle estimated by means of spectronazal X-ray detector. Described are study results of the influence of inclusion's geometric dimensions and of the whole radiation filtration exerted on the value of characteristic angles for different substances. The experimental values of effective atomic numbers are shown to fit well, within the range limited by radiation contrast, the theoretical ones.
Download full-text PDF |
Source |
---|
EJNMMI Phys
January 2025
Department of Nuclear Medicine, Division of Life Sciences and Medicine, The First Affiliated Hospital of USTC, University of Science and Technology of China, Hefei, 230001, Anhui, China.
Single photon emission computed tomography (SPECT), a technique capable of capturing functional and molecular information, has been widely adopted in theranostics applications across various fields, including cardiology, neurology, and oncology. The spatial resolution of SPECT imaging is relatively poor, which poses a significant limitation, especially the visualization of small lesions. The main factors affecting the limited spatial resolution of SPECT include projection sampling techniques, hardware and software.
View Article and Find Full Text PDFJ Comput Assist Tomogr
January 2025
Department of Radiology, College of Medicine, University of Florida, Gainesville, FL.
Purpose: This study evaluated beam quality and radiation dosimetry of a CT scanner equipped with a novel detector and filtration technology called PureVision Optics (PVO). PVO features miniaturized electronics, a detector cut with microblade technology, and increased filtration in order to increase x-ray detection and reduce image noise.
Methods: We assessed the performance of two similar 320-detector CT scanners: one equipped with PVO and one without.
J Comput Assist Tomogr
January 2025
Department of Radiology, College of Medicine, University of Florida, Gainesville, FL.
Purpose: The purpose of this work was to evaluate the image quality of a commercial CT scanner equipped with a novel detector and filtration technology called PureVision Optics (PVO).
Methods: CT number, noise, contrast-to-noise ratio (CNR), modulation transfer function (MTF), and noise power spectrum (NPS) were assessed using the ACR CT Accreditation phantom scanned with various acquisitions at 80 kV, 100 kV, 120 kV, and 135 kV, each with multiple CTDIvol values of 20 mGy, 40 mGy, and 65 mGy. Artifacts were evaluated in an anthropomorphic head phantom, a cadaver head, and in patient studies.
Synthetic aperture X-ray ghost imaging (SAXGI) is proposed to achieve megapixel X-ray ghost imaging together with a reduced number of measurements. As the bucket detector array is artificially generated by post-pixel-binning of the images collected with the same detector as that in the reference arm, the unique advantages of SAXGI are not verified experimentally. In this paper, we developed a systematic solution of the experimental implementation of SAXGI, with the automatic interchange of 2× and 20× optical magnification of the detector for object and reference signal acquisition respectively, together with electronic pixel-binning of the detector.
View Article and Find Full Text PDFWe demonstrate PaCMAN, a ptychography algorithm that can reconstruct high quality images with broadband illumination sources while being robust to shot, detector, and parasitic noise. We extend prior monochromatization work to improve accuracy, especially for discrete spectra, and also demonstrate how PaCMAN can be converted into Ms. PaCMAN, a multi-spectral variant that outperforms multi-spectral ePIE.