A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Intra-operative acoustic hemostasis of liver: production of a homogenate for effective treatment. | LitMetric

Objective: We have shown that High-Intensity Focused Ultrasound (HIFU) can effectively control bleeding from injuries to solid organs such as liver, spleen, and lung. Achievement of hemostasis was augmented when a homogenate of tissue and blood was formed. The objective of this study was to investigate quantitatively the effect of homogenate production on HIFU application time for hemostasis. Possible mechanisms involved in homogenate production were also studied.

Methods: Ten anesthetized rabbits had laparotomy and liver exposure. Liver incisions, 15-25 mm long and 3-4 mm deep, were made followed immediately by HIFU application. Two electrical powers of 80 and 100 W corresponding to focal acoustic intensities of 2264 and 2829 W/cm(2), respectively were used. Tissue and homogenate temperatures were measured. Smear and histological tissue sample analysis using light microscopy were performed.

Results: In treatments with homogenate formation, hemostasis was achieved in 76+/-1.3 s (Mean+/-Standard Error Mean: SEM) at 80 W. In treatments without homogenate formation (at 80 W), hemostasis was achieved in 106+/-0.87 s. At 100 W, hemostasis was achieved in 46+/-0.3 s. The time required for homogenate formation, at 80 and 100 W were 60+/-2.5 and 23+/-0.3 s, respectively. The homogenate temperature was 83 degrees C (SEM 0.6 degrees C), and the non-homogenate tissue temperature at the treatment site was 60 degrees C (SEM 0.4 degrees C). The smear and histological analysis showed significant blood components and cellular debris in the homogenate, with some intact cells.

Conclusion: The HIFU-induced homogenate of blood and tissue resulted in a statistically significant shorter HIFU application time for hemostasis. The incisions with homogenate had higher temperatures as compared to incisions without homogenate. Further studies of the correlation between homogenate formation and temperature must be done, as well as studies on the long-term effects of homogenate in achieving hemostasis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultras.2004.07.002DOI Listing

Publication Analysis

Top Keywords

homogenate formation
16
homogenate
15
hifu application
12
hemostasis achieved
12
hemostasis
8
homogenate production
8
application time
8
time hemostasis
8
smear histological
8
treatments homogenate
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!